14 INT-KWRL
SATEL
Event after 3 readings
[Ev.3 unk.cards] – if this option is enabled, reading in an unknown
card three times will save the event.
Alarm after 3 readings
[Al.3 unk.cards] – if this option is enabled, reading in an unknown
card three times will trigger an alarm. The option is available, if the E
VENT AFTER
3
READINGS
option is enabled.
Code+card
Code OR card
– the user can use code or card for authentication.
Code AND card
– the user must use code and card for authentication.
Follow output
– the authentication method depends on the status of selected output (the
output active – code and card; the output inactive – code or card).
In case of the authentication using code and card, the executed function depends on
the second identifier.
The outputs 255 and 256 cannot be used for controlling the authentication method.
5. Operation
When in active mode, the wireless keypad enables operation and programming of the alarm
system. In order to enter the active mode, press any key on the keypad.
In addition to starting the active mode, pressing a key will also have other
consequences, as appropriate for the given key. The keypad will treat each key
pressing exactly in the same way.
In the active mode, the wireless keypad works much in the same way as the wired keypad.
For the way of using the keypad, please refer to the control panel user and programming
manuals. The manuals are available on the www.satel.eu website.
6. Specifications
Operating frequency band................................................................... 868.0 MHz ÷ 868.6 MHz
Radio communication range (in open area)
ACU-120 ............................................................................... up to 800 m
ACU-270 ............................................................................... up to 400 m
Batteries........................................................................................................... 2 x CR123A 3 V
Standby current consumption, BT1 battery .................................................................0.005 mA
Maximum current consumption, BT1 battery....................................................................50 mA
Standby current consumption, BT2 battery .................................................................0.001 mA
Maximum current consumption, BT2 battery (card reader disabled)................................45 mA
Maximum current consumption, BT2 battery (card reader enabled) ................................90 mA
Environmental class according to EN50130-5 .........................................................................II
Operating temperature range...............................................................................-10°C...+55°C
Maximum humidity ..........................................................................................................93±3%
Enclosure dimensions ................................................................................. 145 x 143 x 25 mm