Profile Series v.G1.5 Mortise Exit Device
10/31/16
Step #3 - Install Exit Chassis
Fig. 3A
Fig. 3C
Latchbolt
Lever arm
Chassis
Lever
1. Route ET harness along track cutout for wood doors or through
access hole for metal doors (Fig. 3A).
2. Mount exit chassis carefully. Do not pinch harness wires.
3. Position exit chassis on door with lever arm under
rear section of mortise lock (Fig. 3B).
4. Secure chassis and ET with (2) 1/4-20 x
2-3/8” flat head machine screws (Fig. 3A).
4. Fasten exit chassis to door using:
• (4) #10 wood screws for wood doors (or)
• (4) #10-24 machine screws for metal doors.
Correct Incorrect
Fig. 4C
Step #4 – Install Cylinder and Secure Chassis
For devices without cylinder, skip this step.
1. Insert cylinder into ET control (Fig. 4A).
2. Mate cylinder tailpiece into hub of exit device chassis.
3. Make sure ET harness is clear of
cylinder and cylinder tailpiece.
4. Secure cylinder to exit chassis
using (2) #12-24 x 1-7/8”
connecting screws (Fig 4B).
5. Position cylinder so that the SARGENT
logo is right-side up (Fig. 4C).
Outside of Door
Inside of Door
Fig. 4B
Fig. 4A
Inside of Door
Fig. 4B
Inside of Door
Fig. 3B
(4) #10 Wood or
#10-24 Machine
Screws
(2) #12-24 x 1-7/8”
Connecting Screws