Installation Instructions
Mortise Lock
IN100 Series
IN100 Series
Mortise Lock
Installation Instructions
14 1-800-810-WIRE • www.sargentlock.com • A8190E
02/28/21
1-800-810-WIRE • www.sargentlock.com • A8190E 15
Copyright © 2016, 2020-2021, Sargent Manufacturing Company
, an ASSA ABLOY Group company
. All rights reser
ved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
6
Lock Installation continued
a. Orient reader so LED lens is at top. (Figure 9A)
b. Feed cable/connector through
door from outside to inside.
c. Install reader to outside of door by aligning
mounting posts with door preparation holes.
Hold reader flush against door while
ensuring proper alignment.
d. Feed reader harness and DPS connectors
through inside mounting assembly and gasket
if required*. (Figure 9A)
IMPORTANT:
Do not run wires through bottom flange hole in
plate - it will damage wires and controller connector.
(Figure 9B, Figure 9C) Route wires around flange, do not route
wires through flange hole. (Figure 9B)
e. Tuck excess cable into wire
hole on inside of door.
f. Begin to secure mounting assembly by par-
tially tightening two (2) through-bolts on
inside of door while ensuring proper align-
ment as reader is secured. (Figure 9B)
g. Secure ground lug with #6-32 ma-
chine screw. (Figure 9C)
LED
Reader
Assembly
with Harness
NOTE: Cable lengths exaggerated
for illustrative purposes.
Fig. 9A
Through-bolt
Gasket*
Mounting
Plate
(7900)
DPS**
Through-bolt
Reader
Harness
Fig. 9B
Fig. 9C
(8200)
DPS**
*NOTE:
•
Gasket is required for outdoor installations
•
Do not use gasket for fire-rated openings
•
If installing with gasket, separate gasket
from mounting plate to feed cables/
connectors through holes as indicated
(Figure 9B)
•
Once cables/connectors are fed through,
reattach gasket to mounting plate
**Note different routing of Door Position Switch harnesses
9 Install outside reader
7900 lockset shown
7900 lockset shown