background image

Installation Instructions

Mortise Lock

IN100 Series

IN100 Series

Mortise Lock

Installation Instructions

2          1-800-810-WIRE • www.sargentlock.com • A8190E 

02/28/21

1-800-810-WIRE • www.sargentlock.com • A8190E        3

Copyright © 2016, 2020-2021, Sargent Manufacturing Company

, an ASSA ABLOY Group company

. All rights reser

ved. 

Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.

1

Warning

Changes or modifications to this device not expressly approved by ASSA ABLOY 
could void the user’s authority to operate the equipment.

FCC:

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the 
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. 
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the 
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not 
occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the 
following measures:

• 

Reorient or relocate the receiving antenna.

• 

Increase the separation between the equipment and receiver.

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• 

Consult the dealer or an experienced radio/TV technician for help.

Industry Canada: 

This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is 
subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any 
interference received, including interference that may cause undesired operation. 
Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des règlements 
d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) 
ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.

“This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be 
installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located 
or operating in conjunction with any other antenna or transmitter.”

Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) 
gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and 
its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful 
communication.
Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un type et 
d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage 
radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotrope 
rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire à l’établissement d’une communication satisfaisante.

Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and SARGENT 
Manufacturing makes no representations or warranties concerning what such impact may be in any specific situation. When 
retrofitting any portion of an existing fire rated opening, or specifying and installing a new fire-rated opening, please consult with a 
code specialist or local code official (Authority Having Jurisdiction) to ensure compliance with all applicable codes and ratings.

To avoid possible damage from electrostatic discharge (ESD), some basic precautions should be used when handling electronic 
components:

• 

Minimize build-up of static by touching and/or maintaining contact with unpainted metal surfaces such as door hinges, 
latches, and mounting plates especially when mounting electronic components such as readers and controllers onto the door.

• 

Leave components (reader and controller) protected in their respective anti-static bags until ready for installation.

• 

Do not touch pins, leads or solder connections on the circuit boards.

!

WARNING

This product can expose you to lead which is known to the state of California to cause cancer and birth defects or other 
reproductive harm. For more information go to 

www.P65warnings.ca.gov

.

Ce produit peut vous exposer au plomb qui, dans l’état de la Californie, est reconnu pour causer le cancer, des anomalies 
congénitales ou d’autres problèmes de reproduction. Pour plus d’informations, visitez: 

www.P65warnings.ca.gov

.

Содержание ASSA ABLOY 7900

Страница 1: ...reparation is critical for proper functioning and security of this lock Misalignment can cause premature wear and a lessening of security A8190E 02 21 Copyright 2016 2020 2021 Sargent Manufacturing Co...

Страница 2: ...hole or in part without express written permission of Sargent Manufacturing Company is prohibited 02 28 21 1 3 2 Table of Contents 5 6 4 7 8 9 10 Warning 3 General Description 4 Hardware Specification...

Страница 3: ...installed and operated with minimum distance 20cm between the radiator and your body This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Under Ind...

Страница 4: ...c security information please contact your local ASSA ABLOY Door Security Solutions sales consultant or call 800 810 WIRE The SARGENT IN100 lock with Aperio Technology makes it easy and cost effective...

Страница 5: ...oductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited 5 Parts Breakdown 1 5 4 3 2 Tools Required 2 Phillips screwdriver Flat blade screwdriver...

Страница 6: ...100 7978 hand fin Lock body without deadbolt with cylinder IN 100 7979 hand fin Lock body without deadbolt without cylinder IN 100 82276 hand fin Lock body with deadbolt with cylinder IN 100 82277 ha...

Страница 7: ...e www intelligentopenings com Field Template A8150 ships with product Door Manufacturer s Template 4713 NOTE Prior to installation all holes must be free of burrs debris and sharp edges 6 Lock Install...

Страница 8: ...f locking piece must face the out side locked side of door To rotate locking piece Fig 2A1 a Position lock body with red surface of locking piece visible b Insert slotted screwdriver into locking piec...

Страница 9: ...See instruction A7983 CAUTION if DPS is not installed or is installed improperly door status monitoring features will not function Only required with the 7900 lock body 6 Lock Installation continued 2...

Страница 10: ...side Note Red indicates locked side outside Fig 3A1 Locking Guide Slot Red color indicates locked side Push In Right Hand Lock Shown If 8200 is type of lock being installed Beveled surface of latch m...

Страница 11: ...lock into the pocket using the harness alone Ensure that the wire harness is not pinched between the lock and the mortise pocket 1 Feed the wire harness 10 pin lock body 4 pin connectors and ground w...

Страница 12: ...crewdriver Outside of Door Fig 4C 4 Outside Cylinder Installation a Slide the spring and the rosette onto the cylinder Fig 4A b Rotate the cylinder into cylinder hole with fingers c Insert key 75 of t...

Страница 13: ...is properly engaged inside lockbody Figure 5B b On inside of door insert spindle into square hole of mortise lock with spin dle slot directed away from mortise lockbody and aligned with set screw hole...

Страница 14: ...urely with a T20 Torx driver d Finish securely tightening two 2 12 24 lockbody screws e Before closing door test that lever is functional and ensure smooth operation of latchbolt Studio 7900 levers us...

Страница 15: ...ill damage wires and controller connector Figure 9B Figure 9C Route wires around flange do not route wires through flange hole Figure 9B e Tuck excess cable into wire hole on inside of door f Begin to...

Страница 16: ...wires through bottom hole in plate it will damage wires and controller connector Route wires around flange do not route wires through flange hole Figure 9A Optional 12 24VDC Power Remote Power Harnes...

Страница 17: ...gure 10A b Ensure proper alignment of board to board connectors while pivoting controller toward door until two tabs on top click securely into place on mounting plate Figure 10B a Place six 6 AA alka...

Страница 18: ...cts both deadbolt and latch 4 Try inside lever ensure it retracts latch and deadbolt if provided 5 Present a valid credential to unlock outside lever turn lever handle to ensure latch retracts Figure...

Страница 19: ...below Some special LED indication schemes are used during lock maintenance actions 2 sec Pairing active Yellow green AH40 Communication Hub ETHERNET LED indication LED on AH40 communication hub indica...

Страница 20: ...mechanism is blocked when closing Continuous red flashes 125 sec every 1 sec Error in lock maintenance required Ten red flashes 125 sec each Repeated every 5 sec if lock can t close Ten red flashes 1...

Страница 21: ...500ms green or red at least one test failed red See table below If a fatal error is detected lock will enter an Error state and continuously indicate fatal error Lock will not read cords or unlock FAT...

Страница 22: ...ions related to access permissions or setup card processing are still present Indication scheme is described by figures below 11 Lock Busy LED Indications 1 5 second delay Continuous yellow flash 1s e...

Страница 23: ...800 810 WIRE www sargentlock com A8190E 23 Copyright 2016 2020 2021 Sargent Manufacturing Company an ASSA ABLOY Group company All rights reserved Reproductions in whole or in part without express wri...

Страница 24: ...or closers exit devices electro mechanical products and access control systems for new construction renovation and replacement applications The company s customer base includes commercial construction...

Отзывы: