49
Saratoga Spa
®
OWNER'S MANUAL
opEratIonS troubLE ShootIng guIdE
probLEM probabLE cauSE SoLutIonS
Spa is not
operating
• Power failure
• GFCI breaker tripped
• Check power source
• Try resetting GFCI breaker. If breaker
continues to trip, contact your dealer.
Spa is not
heating
• Dirty filters
• Temperature setting too low
• Air trapped in circulation line
• Spa could be in Economy (ECN)
or sleep (SLP) mode
• Clean the filters
• Increase the set temperature
• Using a garden hose, force water through
Whisper Clean® cartridge opening or
loosen the bottom heater union to allow
trapped air to escape.
• Press the TEMP then JETS button to
adjust Heat Modes FC is continuous,
operates same as standard mode
setting
Poor or
no water
flowing
through
the jets
• Dirty filters
• Inadequate water level
• Air lock
• Clean the filters
• Fill spa to 2" above filters
• Prime the pump(s) by loosening unions
on the pump(s) until air can be heard
escaping, then tighten unions.
Spa light out
• Burned out Color Blast™ Light
• Light not turned on
• Replace with new Color Blast™ Light
• Press the light key to desired style and
performance
Pump(s)
turn off
unexpectedly
• Automatic 15 minute shut off
• Pump(s) may have overheated.
Built in protective overheat
shut off
• Press jets button again to start another
15 minute cycle
• Let pump sit for about 10-15 minutes.
Allow pump to cool down, keep vented
areas on access panel free from blockage.