background image

28

Saratoga Spa

®

 

OWNER'S MANUAL

1 | VErSa-FLo™ MIcro VaLVE 

Controls the amount of water flowing through the  
Power Massage® Jet & RelaxStream™ Waterfall 1A & 1B

•  The 3 o’clock position operates a flat stream flow 1A.
•  The 9 o’clock position operates the RelaxStream™ Waterfall 1B.
•  The 6 o’clock position operates both at a reduced performance.

2 | VErSa-FLo™ MIcro VaLVE

Controls the amount of water flowing through the Power Massage® Plus Jet 2A

•  The 3 o’clock position operates an angled stream flow. 
•  The 9 o’clock position operates a flat stream flow
•  The 6 o’clock position operates both at a reduced performance.

3 | VErSa-FLo™ VaLVE 

Controls the amount of water flowing through Jets in 3A & 3B

•  The 3 o’clock position operates the 12 jet seat flow 3A.
•  The 9 o’clock position operates the foot dome jet flow 3B.
•  The 6 o’clock position operates both at a reduced performance.

1a

1

5

3b

2a

3a

3

1b

5

4a

4

rEgEnt

Jet System Menu

1

Содержание Adelphi

Страница 1: ...Luxury Edition O w n e r s M a n u a l s a r a t o g a s p a ...

Страница 2: ... 3554 kg 500 lbs 227 kg 620 lbs 281 kg 750 lbs 340 kg 750 lbs 340 kg 920 lbs 417 kg 920 lbs 417 kg 1200 lbs 544 kg Thank you for your recent Saratoga Spa Purchase This owners manual has been designed to acquaint you with your Saratoga Spa s operation and general maintenance Keep this manual available for future reference If you have any questions regarding your Saratoga Spa contact your local deal...

Страница 3: ... 25 Canfield 26 27 Regent 28 29 Lincoln 30 31 Empire 32 33 Broadway 34 35 Equipment Maintenance Jet Valve Maintenance 36 Roto Stream Valve Maintenance 36 37 LED Light Bulb Replacement 37 Control Panel FUNCTIONS Main Control Panel 38 Main Control Panel Buttons and Digital Display 38 Temperature Control 38 Operating the Hydro Pumps 39 Jet Buttons 39 Light Control Ambiance Lighting System 40 Optional...

Страница 4: ...or conduit within five feet 1 5 m of the unit as needed to comply with local requirements To reduce the risk of electrocution replace all damaged cords immediately Failure to do so may result in death or serious personal injury due to electrocution Do not connect any auxiliary components for example additional cable speakers headphones or other audio components to the audio system unless approved ...

Страница 5: ...mponents The use of drugs alcohol or medication before or during spa use may lead to unconsciousness with the possibility of drowning Persons using medications should consult a physician before using a spa some medication may cause a user to become drowsy while other medication may affect heart rate blood pressure and circulation Persons taking medications which induce drowsiness such as tranquili...

Страница 6: ...ion can greatly increase the risk of fatal hyperthermia in hot tubs and spas To Reduce The Risk of Injury The water in the spa should never exceed 104 F 40ºC Water temperatures between 100 F 37 7ºC and 104 F 40ºC are considered safe for a healthy adult Lower water temperatures are recommended for extended use exceeding ten minutes and for young children Extended use can cause hyperthermia Pregnant...

Страница 7: ...ensed electrical contractor Test the Ground Fault Circuit Interrupter s once a month Place the spa on a level load bearing surface Don t Allow children to climb onto the spa cover Allow children to have unsupervised access to the spa Leave the Saratoga Spa exposed to the sun without water or the cover in place Exposure to direct sunlight can cause solar distress of the shell material Lift or drag ...

Страница 8: ...6 2 13 m 2 29 m 0 97 m 1609 L 340 kg 1 949 kg Lincoln 90 94 40 525 gal 920 lbs 5 302 lbs 6 7 2 29 m 2 39 m 1 02 m 1988 L 417 kg 2 405 kg Empire 89 93 40 525 gal 920 lbs 5 302 lbs 6 7 2 26 m 2 36 m 1 02m 1988 L 417 kg 2 405 kg Broadway 92 108 40 795 gal 1200 lbs 7 835 lbs 9 2 34 m 2 74 m 1 02 m 3010 L 544 kg 3 554 kg Due to the risk of property damage and injury the manufacturer of the Saratoga Spa...

Страница 9: ...ves C Power Massage Jets D Power Stream Jets E Cluster Jets F Standard Jets G Storm Jets H Vortex Jet Circulation I Whisper Clean Jet J Footwell Spa Drain K Relax Stream Waterfall L Backlit Digital Control Panel M Microban Filtration N Toploading Skimmer O Pillows P Mood Light Adelphi 6 Drain Valve 7 Mood Light 8 Bonding Terminal 9 Shut Off Valves b a L P F O C F F O B a CO f E H N M D D I j g E E...

Страница 10: ...uxe Jets H Storm Jets I Vortex Jet Circulation J Whisper Clean Jet K Footwell Spa Drain L Relax Stream Waterfall M Backlit Digital Control Panel N Microban Filtration O Toploading Skimmer P Pillows Q Mood Light Putnam 6 Whisper Zone Ozonator Located behind the Purity Circulation Pump Standard on XL 7 Drain Valve 8 Mood Light 9 Bonding Terminal 10 Shut Off Valves A B C P P E G G D D h N O J K P G M...

Страница 11: ...tal Control Panel O Microban Filtration P Toploading Skimmer Q Pillows R Roto Stream Valves Canfield Operations Center 1 1 Two Speed Hydro Pump 2 1 Single Speed Hydro Pump 3 4 kW Heater 4 Purity Circulation Pump 5 220V Power Pack 6 Whisper Zone Ozonator Located behind the Purity Circulation Pump Standard on XL 7 Drain Valve 8 Mood Light 9 Bonding Terminal 10 Shut Off Valves f Q i A M i g Q a i k p...

Страница 12: ...n Filtration Q Toploading Skimmer R Pillows S Mood Light Regent Operations Center 1 1 Two Speed Hydro Pump 2 1 Single Speed Hydro Pump 3 4 kW Heater 4 Purity Circulation Pump 5 220V Power Pack 6 Whisper Zone Ozonator Located behind Purity Circulation Pump Standard on Regent Special Edition 7 Drain Valve 8 Mood Light 9 Bonding Terminal 10 Shut Off Valves C M Y CM MY CY CMY K a DR F R i R D G H a b ...

Страница 13: ... Microban Filtration P Toploading Skimmer Q Pillows R Mood Light S Satellite Control Button Lincoln Operations Center 1 1 Two Speed Hydro Pump 2 2 Single Speed Hydro Pumps 3 4 kW Heater 4 Purity Circulation Pump 5 220V Power Pack 6 Whisper Zone Ozonator Located behind Purity Circulation Pump Standard on XL 7 Drain Valve 8 Mood Light 9 Bonding Terminal 10 Shut Off Valves S m h h h i q b c h a q e d...

Страница 14: ...Q Backlit Digital Control Panel R Microban Filtration S Toploading Skimmer T Pillows U Mood Light V Satellite Control Button Empire Operations Center 1 1 Two Speed Hydro Pump 2 2 Single Speed Hydro Pumps 3 4 kW Heater 4 Purity Circulation Pump 5 220V Power Pack 6 Whisper Zone Ozonator Located behind the Purity Circulation Pump Standard on XL 7 Drain Valve 8 Mood Light 9 Bonding Terminal 10 Shut Of...

Страница 15: ...eam Waterfall P Backlit Digital Control Panel Q Microban Filtration R Toploading Skimmer S Pillows T Mood Light U Satellite Control Button Broadway Operations Center 1 1 Two Speed Hydro Pump 2 2 Single Speed Hydro Pumps 3 4 kW Heater 4 Purity Circulation Pump 5 220V Power Pack 6 Whisper Zone Ozonator Located behind the Purity Circulation Pump Standard on XL 7 Drain Valve 8 Mood Light 9 Bonding Ter...

Страница 16: ...at type of climate you live in In a climate with cold snowy winters you may want to consider locating the spa close to the house for easy access In climates where it is normally warm or hot year round it would be recommended to place the spa in a shaded or cool area With deck installations it is recommended that a qualified building contractor or structural engineer review the weight the deck can ...

Страница 17: ...del spas must be connected to a dedicated 220 volt 50 Amp grounded circuit The term dedicated means the electrical circuit is not being used for any other electrical items lights appliances etc If the spa is connected to a non dedicated circuit overloading will occur and nuisance tripping of the GFCI breaker switch at the house breaker panel will occur A ground lug connector is provided on the ext...

Страница 18: ...an No 6 AWG 7 All field installed metal components such as rail ladders drains or other similar hardware within 10 ft 3m of the spa or hot tub shall be bonded to the equipment grounding bus with copper conductors not smaller than No 6 AWG 8 Replace the control box cover and securely tighten the fastening screws Close and secure the equipment compartment panel Always use copper wire only 3 wire wit...

Страница 19: ...e spa plumbing Through the shipping process water may have spotted the spa shell You may need to wipe down the shell with a soft cloth Please read and follow the start up instructions to ensure a successful start up or refill Inspect and clean spa shell of any debris Do not turn power on to spa unless filled with water to appropriate level See Page 18 The spa pack must never be operated without wa...

Страница 20: ...eck all plumbing clamps unions and drain valve connections for leaks 3 Re install filter cartridges and screen adapters by turning them clockwise Exit garden hose from the spa 4 At this point turn on the spa control system by turning on the GFCI breaker When your spa is first actuated it will go into Priming Mode indicated by Pr During this mode the heater is disabled to allow the priming process ...

Страница 21: ... Whisper Clean Jet The combination of the Whisper Clean and Vortex Jet return systems help the Whisper Clean System to circulate water from the surface and bottom level of the spa The Whisper Clean Jet also introduces temperature controlled water and ozone into the spas footwell area 24 hours a day A slow or non moving Whisper Clean Jet may indicate that the filter cartidges areobstructed with dir...

Страница 22: ...andard Jet Category The Mini Swirl Jet has an adjustable eyeball for directional or rotational use To change from directional to rotational with finger simply adjust inner nozzle to the rotating position Mini Twin Roto Jet Standard Jet Category This dual nozzle jet gives rotational intensities over focused muscle areas Mini Tri Flo Massage Jet Standard Jet Category A rotating dual nozzle diffused ...

Страница 23: ... smaller version of the Gatling a rotating dual nozzle diffused by seven holes creates a pulsating body massage Multi Flo Jet Deluxe Jet Category The smaller version of the Veri Flo Jet this jet delivers multiple pressure point flow into several locations of muscle area and has an interchangeable design that gives relief to a variety of areas Xtreme Flo Jet Storm Jet Category The Xtreme Flo jet pr...

Страница 24: ...s can be adjusted by the following zones Saratoga Spa uses six different ways to adjust the jet therapy zones The Roto Stream Valves ProJet Stream Valves Versa Flo Valves and Versa Flo Micro Valves give the user the ability to control the different Jet Therapy Zones The Air Control valve controls the intensity of the Jets by opening or restricting airflow The following pages will discuss the diffe...

Страница 25: ...r Keep this in mind when the following pages discuss 12 3 6 or 9 o clock position settings The Versa Flo Air Control Valve and Versa Flo Micro Valve can only be rotated 180º The Projet Stream Valve controls the Projet Stream Jets Jet SYSTEM MENUS Jet Therapy Zones Note Luxury Spa ES models do not use the Roto Stream Sequencing System on the Canfield Lincoln Empire and Broadway or Jet Pump 3 on the...

Страница 26: ...nce 2 VERSA FLO MICRO VALVE Controls the amount of water flowing through the Power Massage Jet 2A 2B The 3 o clock position operates a flat stream flow 2A The 9 o clock position operates the RelaxStream Waterfall 2B The 6 o clock position operates both at a reduced performance 3 VERSA FLO AIR CONTROL VALVE This Valve adds or restricts intensity to jets when pump s are operating Note Descriptions a...

Страница 27: ... at a reduced performance 2 VERSA FLO MICRO VALVE Controls the amount of water flowing through the Power Massage Plus Jet 2A The 3 o clock position operates an angled stream flow The 9 o clock position operates a flat stream flow The 6 o clock position operates both at a reduced performance 3 VERSA FLO AIR CONTROL VALVE This Valve adds or restricts intensity to jets when pump s are operating Note ...

Страница 28: ...nt of water flowing through the Power Massage Plus Jet 2A The 3 o clock position operates an angled stream flow The 9 o clock position operates a flat stream flow The 6 o clock position operates both at a reduced performance 3 VERSA FLO VALVE Controls the amount of water flowing through Jets in 3A 3B The 3 o clock position operates the foot dome jet flow 3A The 9 o clock position operates the 12 j...

Страница 29: ...urns off the Roto Stream valve 4A from sequencing the six jets in seat 4B The 9 o clock position turns on the Roto Stream valve 4A and begins sequencing the six jets in seat 4B 5 VERSA FLO AIR CONTROL VALVE This Valve adds or restricts intensity to jets when pump s are operating Note Descriptions are based upon valve operation from within the spa Not Available on ES Models ...

Страница 30: ...VE Controls the amount of water flowing through the Power Massage Plus Jet 2A The 3 o clock position operates an angled stream flow The 9 o clock position operates a flat stream flow The 6 o clock position operates both at a reduced performance 3 VERSA FLO VALVE Controls the amount of water flowing through Jets in 3A 3B The 3 o clock position operates the 12 jet seat flow 3A The 9 o clock position...

Страница 31: ...m Seat 4A 5 VERSA FLO AIR CONTROL VALVE This Valve adds or restricts intensity to jets when pump s are operating Note Descriptions are based upon valve operation from within the spa Note The Regent has the Roto Stream Sequencing System as an optional feature The manual version of the Roto Stream is a standard feature on the Regent ...

Страница 32: ...amount of water flowing through the Power Massage Plus Jet 2A The 3 o clock position operates an angled stream flow The 9 o clock position operates a flat stream flow The 6 o clock position operates both at a reduced performance 3 PROJET STREAM VALVE Controls the operation of the ProJet Stream Jets 3A Rotating the ProJet Stream Valve completely counter clockwise opens water flow to the ProJet Stre...

Страница 33: ...tream valve 4A from sequencing the six jets in seat 4B The 9 o clock position turns on the Roto Stream valve 4A and begins sequencing the six jets in seat 4B 5 VERSA FLO AIR CONTROL VALVE This Valve adds or restricts intensity to jets when pump s are operating Note Descriptions are based upon valve operation from within the spa ES Models do not have the 3rd jet pump Not available on ES Models ...

Страница 34: ...ion of the ProJet Stream Jets 2A Rotating the ProJet Stream Valve completely counter clockwise opens water flow to the ProJet Stream Jets Rotating the ProJet Stream Valve completely clockwise closes the water flow to the ProJet Stream Jets 3 VERSA FLO MICRO VALVE Controls the amount of water flowing through the Power Massage Plus Jet 3A The 3 o clock position operates a flat stream flow The 9 o cl...

Страница 35: ...encing the six jets in seat 4B 5 VERSA FLO VALVE Controls the amount of water flowing through Jets in 5A 5B The 3 o clock position operates the foot dome jet flow 5A The 9 o clock position operates the 14 jet seat flow 5B The 6 o clock position operates both at a reduced performance 6 VERSA FLO AIR CONTROL VALVE This Valve adds or restricts intensity to jets when pump s are operating Note Descript...

Страница 36: ...sage Jet 2 RelaxStream Waterfalls 2A 2B The 3 o clock position operates a flat stream flow 2A The 9 o clock position operates 2 RelaxStream Waterfalls 2B The 6 o clock position operates both at a reduced performance 3 PROJET STREAM VALVE Controls the operation of the ProJet Stream Jets 3A Rotating the ProJet Stream Valve completely counter clockwise opens water flow to the ProJet Stream Jets Rotat...

Страница 37: ...e 6 VERSA FLO MICRO VALVE Controls the amount of water flowing through the Power Massage Plus Jet 6A The 3 o clock position operates a flat stream flow The 9 o clock position operates an angled stream flow The 6 o clock position operates both at a reduced performance 7 VERSA FLO MICRO VALVE Controls the amount of water flowing through the Power Massage Jet 2 RelaxStream Waterfalls 7A 7B The 3 o cl...

Страница 38: ...ete valve assembly by pulling outward 4 Clean or remove debris from valve or diverter 5 Re assemble and re thread valve cover Roto Stream Valve Maintenance The Roto Stream valve is another unique feature that Saratoga Spa uses for Hydrotherapy It is necessary to clean the valve to ensure that the Roto Stream valve continues to perform well The following instructions will walk you through the steps...

Страница 39: ...ult in internal mechanical damage and is not covered by warranty Please contact your dealer if they need to be replaced Replacing the Spa Color Blast LED Light The spa Color Blast LED Light is located inside of the equipment compartment Remove the front access panel by first removing the screws on the access panel Then locate the light housing mounted to the spa shell Use a flathead screwdriver pl...

Страница 40: ...ight and activate or deactivate the hydro jet pump s The control panel also has a digital display that displays the spa diagnostics ie temperature setting jet functions or error messages Temperature Control The set temperature range is from 80 F 26 C to 104 F 40 C The temperature of the spa water will automatically be 100 F 37 C the first time that power is applied This is the default temperature ...

Страница 41: ...n high speed Jets 3 Button Empire Lincoln and Broadway XL Models Only Activates the hydro jet pump 3 for maximum hydrotherapy jet action Press the Jets 3 button once for high speed and again to turn the pump off When the pump is activated the indicator above the Jets 3 button will light up The pump will turn off automatically after 15 minutes on high speed Note The spa light will begin flashing 15...

Страница 42: ...e last measured spa temperature displayed is current only when the pump has been running for at least 2 minutes Std will be displayed momentarily when you switch into Standard Mode Economy Mode heats the spa to the set temperature only during your chosen economy mode cycles as needed Ecn will display solid when temperature is not current and will alternate with temperature when temperature is curr...

Страница 43: ...anel is located on the spa collar opposite the main panel topside control All the features that are available for Jets 2 are accessible by using this smaller satellite panel Temperature and light functions are not accessible through the smaller satellite panel Spa Care and water Maintenance General Information Your Saratoga Spa is manufactured from the highest quality most durable materials availa...

Страница 44: ...e Adelpi which has standard 12 filters As with any filtering system the filter cartridges may become clogged with particles body oils or calcification resulting in poor water quality and reduced water flow It is important to maintain a clean unobstructed filtering system A reduced water flow may cause failure of the circulation pump or for the circulation pump to shut down If the circulation of wa...

Страница 45: ... remove and replace the spa pillows 1 Carefully lift one end of the pillow away from the spa shell 2 Continue lifting one end until it is released from the attachment bar on the spa shell Do the same to loosen the other end of pillow To reinstall the spa pillow carefully bend the pillow slightly to allow the slit on the back of the pillow to slip over the attachment bar retainer on the spa shell 3...

Страница 46: ... of saddle soap follow directions on the container or vinyl conditioning cream Important reminders Do unlock and release all cover locks before attempting to open cover Do remove snow buildup to avoid damage of the foam core from the additional weight of the snow not covered under warranty Do lock cover lock straps to secure the cover when the spa is not in use Do not drag or lift the spa cover us...

Страница 47: ... hose down the filter cartridge openings and vacuum up any water from filter campartment 12 Disconnect the unions at the circulation pump from both the return and suction side of pump 13 Remove circulation pump 14 Vacuum up both suction and return side of the circulation pump 15 Reverse vacuum and blow out each side of circulation pump Also blow out and vacuum any water from the hoses coming into ...

Страница 48: ...ws a pH equal to 7 0 is neutral A pH below this point is acidic and a pH above this point is basic Test pH weekly Recommended Range 7 2 to 7 8 If the pH is too low it can 1 Corrode metal surfaces 2 Use excess sanitizer 3 Irritate bathers skin and eyes Adjusting pH To raise pH add a granular pH Increaser or sodium carbonate at the rate suggested on the container To lower pH add a granular pH Decrea...

Страница 49: ...ng lower levels of calcium hardness Disinfectant Brominating Tablets Granular Bromine and Granular Chlorine are popular disinfectants and are particularly well suited to compliment your ozone purification system spa They are also very suitable products in water with elevated temperatures Brominating Tablets and Granular Bromine are effective as a spa water sanitizer and disinfectant Follow manufac...

Страница 50: ...hardness 125 150 Non chlorine shock weekly or as needed based on spa use Test pH total alkalinity and calcium hardness weekly Test disinfectant daily Spa test kits are available through your Saratoga Spa Dealer Ozone Generators The Saratoga Spa Luxury XL Line comes equipped with an ozone generator Optional on the ES Line It automatically produces ozone 24 hours a day through our Whisper Clean Syst...

Страница 51: ...e TEMP then JETS button to adjust Heat Modes FC is continuous operates same as standard mode setting Poor or no water flowing through the jets Dirty filters Inadequate water level Air lock Clean the filters Fill spa to 2 above filters Prime the pump s by loosening unions on the pump s until air can be heard escaping then tighten unions Spa light out Burned out Color Blast Light Light not turned on...

Страница 52: ... to operate main control panel Panel may have malfunctioned Contact your dealer Water does not clear up Bad water chemistry Dirty filter cartridges Ozone generator not operating Bromine chlorine residual levels too low Balance water Clean or replace filters Locate ozone generator a purple ultraviolet light to be illuminated in the ozone generator Adjust Bromine chlorine levels Shock if necessary M...

Страница 53: ... persists contact your dealer or service organization May appear temporarily in an overheat situation and disappear when the heater cools Snb Spa is shut down The sensor that is plugged into the Sensor B jack is not working If the problem persists contact your dealer or service organization May appear temporarily in an overheat situation and disappear when the heater cools SnS Sensors are out of b...

Страница 54: ...n 2 The side to the RIGHT is the this orientation is the your moving side on the all Saratoga models 3 When removed from the pallet the spa must be RIGHT SIDE DOWN for all the moving and deliveries 4 The RIGHT spa side is a reinforced for moving however a cart must be used that will accommodate the width of the spa when in the upright position When using a cart narrower than the spa a wooden panel...

Страница 55: ... damage caused by a dirty clogged or calcified filter cartridge damage to the spa components or spa surface determined to have been caused by improper water maintenance or improper use of chemicals refer to pages 46 48 of this owners manual damage caused by allowing undissolved spa sanitizing chemicals to lie on the spa surface no spa surface material can withstand this kind of abuse and damage to...

Страница 56: ...d C l e a n S p a S h e l l S p r a y C l e a n F i l t e r C a r t r i d g e S o a k F i l t e r C a r t r i d g e C o m p l e t e S p a W a t e r B a l a n c e C l e a n a n d C o n d i t i o n V i n y l S p a C o v e r W i n t e r i z e S p a M i s c e l l a n e o u s S e r v i c e ...

Страница 57: ...d C l e a n S p a S h e l l S p r a y C l e a n F i l t e r C a r t r i d g e S o a k F i l t e r C a r t r i d g e C o m p l e t e S p a W a t e r B a l a n c e C l e a n a n d C o n d i t i o n V i n y l S p a C o v e r W i n t e r i z e S p a M i s c e l l a n e o u s S e r v i c e ...

Страница 58: ...r a y C l e a n F i l t e r C a r t r i d g e S o a k F i l t e r C a r t r i d g e C o m p l e t e S p a W a t e r B a l a n c e C l e a n a n d C o n d i t i o n V i n y l S p a C o v e r W i n t e r i z e S p a M i s c e l l a n e o u s S e r v i c e Spa Care And Maintenance Record ...

Страница 59: ...F i l t e r C a r t r i d g e S o a k F i l t e r C a r t r i d g e C o m p l e t e S p a W a t e r B a l a n c e C l e a n a n d C o n d i t i o n V i n y l S p a C o v e r W i n t e r i z e S p a M i s c e l l a n e o u s S e r v i c e Spa Care And Maintenance Record ...

Страница 60: ...33 Wade Road Latham NY 12110 1 800 444 9977 fax 518 782 0632 www SaratogaSpas com 25013 12 ...

Отзывы: