19
Saratoga Spa
®
OWNER'S MANUAL
5. After the pumps are primed turn off by pressing the Jet(s) button(s). Next manually exit
the priming mode by pressing either the Warm or Cool button . After you have manually
exited the priming mode the display will show the set temperature, which defaults at
100° F/ 37°C, followed by two dashes (--). This will last for two minutes while the water
temperature is determined . Push the Warm or Cool button to the desired setting .
6 . Re-install filter cover and allow spa to heat to desired set temperature: this normally
takes 24 hours .
7 . Water must be balanced and shocked upon start-up . See your dealer or pages 46-48 of this
manual for details . This procedure must be repeated each time the spa is drained and refilled .
8 .
The Whisper Clean® Jet
The combination of the Whisper Clean® and Vortex Jet™ return systems help the
Whisper Clean® System to circulate water from the surface and bottom level of the spa .
The Whisper Clean® Jet also introduces temperature controlled water and ozone into the
spas footwell area 24 hours a day . A slow or non-moving Whisper Clean® Jet may indicate
that the filter cartidges areobstructed with dirt, body oils or calcification . Follow the filter
cartridge cleaning procedures in this manual .
It is recommended to press and release the ground fault circuit interrupter (GFCI)
RESET button monthly to verify GFCI is working properly .
Important:
A pump should not be allowed to run without priming for more than 2 minutes . Under NO
circumstances should a pump be allowed to run without priming beyond the end of the 4
minutes priming mode . Doing so may cause damage to the pump and cause the system to go
into an overheat condition .
Whisper Clean® Jet
!
!