-22-
ASS'Y POWER
Hot circuit
AC-INPUT
CPU IC801
and
I / O
EXPANDER
IC1831
SUB POWER
System Control
INTERLOCK SW
FUSE
SW902
F901
DC out
WARNING
TEMP.
READY
PO
WER-ON/OFF
IIC-SCL & SD
A
AC
DC out
I / O
EXPANDER
POWER
CONTROL
SWITCH
INDICATORS
FAN
ON/OFF
FANS
FANS
PO
WER F
AILURE
CONTROL
LAMP
REPLACE
LAMP
Always
Switched
16V /9V /6.25V /-6V
* NO POWER -1
Troubleshooting
Power on/off
Fan on/off
PFC on/off
Ballast on/off
Power sw
OFF
Power sw
ON
Cooling time after power off.
400~600ms(Stability period of PFC.)
Timing chart
Are you thinking about turning
on the projector without the
lamp cover?
Remember that the interlock
switch is opened during disas-
sembling the cabinet. The projec-
tor can't be turned on. (Some of
the service personnel forget it
often.) When you turn on the pro-
jector without cabinet, press and
hold the lever of the interlock
switch.
Is the fuse (F901) blown?
The fuse may be opened
when either the LAMP indica-
tor or the READY indicator
isn't Illuminated. Check the
fuse. For continued safety,
replace it with a new fuse of
the same type.
Is the Interlock switch
opened?
When the lamp cover isn't
attached correctly or the boss
inside the lamp cover is bro-
ken, the projector can't be
turned on. Check the boss
and the Interlock switch
(SW902). Refer to figure on
page 4.
Are the LAMP
indicator(red) and READY
indicator(green) light?
If the LAMP and READY
indicators are not illuminat-
ed, check the primary cir-
cuit and S5V of standby
power supply circuit.
Check that the
POWER FAIL sig-
nals are correct.
L : Abnormality
Check that the
Vcc-voltages are
correct.
Check that the POWER
ON/OFF signal is correct.
L : Abnormality
Check that the Fan
on/off signal is cor-
rect.
L : Abnormality
Check that the IIC
Bus signals for fan
control are correct.
Refer to page 24.