49
Others
Appendix (Continued)
Code
Function
0
SPEED CURVES
11
12
13
14
15
16
8XXX
900X
910X
(*) The Pelco D protocol accepts a value of 63 at maximum speed. Correct operation is not guaranteed
when set at a higher speed.
ZONE
20
21
10X
20X
LENSES
40
41
42
AUTOIRIS
50
51
52
ON SCREEN INFORMATION
60
61
62
¡
PELCO
Pan 0 position
First speed curve (speed values: 1, 5, 10, 20, 30, 45, 63).
Second speed curve (speed values: 1, 10, 20, 30, 40, 50, 63).
Third speed curve (speed values: 10, 15, 20, 25, 30, 45, 63).
Fourth speed curve (default setting) (speed values: 29, 37, 45, 50, 55, 59, 63).
Fifth speed curve (speed values: 10, 15, 20, 30, 40, 50, 63).
Sixth speed curve (Can be user customized, but has default settings:
10, 15, 20, 30, 55, 100, 255). (*)
XXX = 000 – 255
: Speed value(*)
X = 1 - 7
: Speed number. Values can be allocated.
X = 1 - 7
: Dome camera operation test at No. X uniform speed.
To stop the test, move the joystick.
Example:
“8007”
: Speed value equal to 7
(X=007)
“9001”
: The 7 speed value is allocated to Speed No. 1
(X=1)
.
... Writes speed value into speed No. 2, 3, 4, 5, 6, etc.
“8138”
: 138
(X=138)
speed value
“9007”
: Allocates speed value 138 to speed No. 7
(X=7)
.
To test speed No. 7 next:
“9107”
: Dome camera moves at uniform speed of 138
(X=7)
.
“16”
: Hereafter, whenever the joystick is moved, the dome camera moves at the speed
allocated to the sixth speed curve
(X=16)
.
Begins zone scan.
Ends zone scan.
X = 1 – 8
: Sets beginning of zone.
X = 1 – 8
: Sets end of zone.
Auto-focus ON
Auto-focus OFF
Automatically turn auto-focus ON
Auto iris ON
Auto iris OFF
Automatically turn auto iris ON
Automatic gain control device ON
Automatic gain control device OFF
Automatic gain control device AUTO
04̲L8CSD̲WA̲Misc̲GB 07.4.12 2:01 PM ページ 49