46
Others
Appendix
■
Special code table
These functions can be loaded by entering their special codes.
ERNITEC SATURN........................................................ 46
MARK MERCER ............................................................ 47
PELCO............................................................................ 49
SENSORMATIC ............................................................. 51
¡
ERNITEC SATURN
Code
Function
AUTOPAN
301
302
XXX
PATROL
1000
1XXX
2000
2XXX
3XXX
OTHER FUNCTIONS
4XXY
4000
400
500
9999
Saves the current position of the first limit switch.
Saves the current position of the second limit switch.
XXX = 0 – 255
: Auto-pan speed (0=min, 255=max)
Note: Cannot use with Saturn type.
Deletes patrol order.
XXX = 1 – 128
: Writes preset position “XXX” into patrol order.
Makes patrol order valid.
X = 001 – 128
: Deletes preset position “XXX” from patrol order.
X = 000 – 255
: Waiting time (in seconds) upon reaching specified position
Example:
“1000”
Deletes previously defined order.
“1001”
Writes preset position “1” into order.
“1005”
Writes preset position “5” into order.
“1006”
Writes preset position “6” into order.
“2005”
Deletes preset position “5”.
Dome cameras can be set to automatically move to the “return position” after a set
stopping time passes.
XX = 01 – 99
: “Return position” (Cannot select positions No. 100 to No. 128)
Y = 0 - 9
: Return time
0
: 10 seconds,
1
: 20 seconds,
2
: 30 seconds,
3
: 40 seconds,
4
: 1 minute,
5
: 2 minutes,
6
: 5 minutes,
7
: 10 minutes,
8
: 20 minutes,
9
: 40 minutes
Invalidates movement to “return position”.
Example:
“4216”
: After stopping for 5 minutes
(Y=6)
, move to position 21
(XX=21)
.
Text display/non-display (switch)
Backlight compensation ON/OFF (switch)
Initializes the dome camera internal memory.
04̲L8CSD̲WA̲Misc̲GB 07.4.12 2:01 PM ページ 46