Valid address range: 0 to 127
Select [MENU] and choose “BACK” or “END” to complete the setting.
The [BAUD RATE] and [TERMINATE] menu items are displayed on the screen.
Use the
/
button to select [PROTOCOL], and use the
/
button to select the
communication protocol.
Available settings:
Use the
/
button to select [ADDRESS], and press the
button.
The ADDRESS setting screen appears.
Use the
button to select the digit and use the
/
button to enter the number, and press
button. Repeat the procedure until the entire address is entered.
The SYSTEM screen appears again.
Valid address range:
Use the
/
button to select [BAUD RATE], and use the
/
button to select the baud rate
used for the connection.
Available settings: 19200, 9600, 4800, 2400
Use the
/
button to select [TERMINATE], and use the
/
button to select the termination
setting.
When you connect multiple devices, set the termination setting to “ON” on devices at both ends.
Select [MENU] and choose “BACK” or “END” to complete the setting.
3
1
SANYO: Supports Sanyo’s SSP/fast SSP.
PELCO: Supports PELCO-D.
2
3
When [PROTOCOL] is set to “SANYO”: 0 to 127
When [PROTOCOL] is set to “PELCO”: 0 to 255
4
5
6
72 / 100