- 4 -
English
PART NAMES • SETTINGS • SETUP
1
■
Settings
1
SW2
2
SW1
1 2 3
1 2 3
JP4
JP3
3
JP3
4
JP4
3
Termination
setting pins
4
Communication
setting pins
1
Protocol and communication speed settings
☞
Protocol setting
This sets the communication protocol to use for the
camera.
The default setting is the “SANYO” protocol (all OFF).
List of Protocol Settings
☞
Communication speed setting
The default setting is “19200”.
2
Address settings
The default setting is “000” (all OFF).
Refer to “LIST OF ADDRESS SETTINGS (SW1)” for
address settings. (See p42)
3
Termination setting (JP3)
The termination connection setting must be made if this
camera is connected to a network system and it is in the
termination connection position.
The default setting is OFF (pins 2–3), so pull out the circuit
board and set JP3 to ON (short pins 1–2), then return the
circuit board to its original position.
If the camera is connected to a network system and it is
not in the termination connection position, the setting does
not need to be changed.
4
Communication setting (JP4)
The camera can be set for either RS-485 or coaxial
(default setting) communication.
The factory default setting is for coaxial communication
(pins 1–2), so that if you would like to use RS-485 control,
pull out the circuit board, change the setting to RS-485
(pins 2–3) and then reinsert the circuit board.
Protocol
SW2 number
1
2
3
4
5
6
SANYO
PELCO_D
ON
Communication
speed (bps)
SW2 number
7
8
2400
OFF
OFF
4800
ON
OFF
9600
OFF
ON
19200
ON
ON
1
2
3
4
5
6
7
8
ON
Protocol
Communication speed
SW2
Pin positions
Termination settings
1–2
ON
2–3
OFF
Pin positions
Connection method
setting
1–2
Coaxial (COAX)
2–3
RS485
1
2
3
4
5
6
7
8
ON
SW1
VCC-9000EBCP/EBSP, VCC-9100EBCP/EBSP
! "#$%&'
Содержание VCC-9000EBCP/EBSP