PLC-XW200/250 Expand Serial Command Functional Specifications
58 / 64
9.11.15 CR_RCODE Command
Command “CR_RCODE”[CR]
Details
Get selected Remote Control Code
Response
Acceptable
“000_%a”[CR]
%a
“001” --------------------------- Code1 is selected
“002” --------------------------- Code2 is selected
Unacceptable “Error Code” [CR]
9.11.16 CR_SECURITY Command
Command “CR_SECURITY” [CR]
Details
Get Security Mode setting status
Response
Acceptable
“000_%1[CR]
%1
“ON” ------------- PJ Lock setting on Menu is ON-1 or ON-2
“OFF” ------------PJ Lock setting on Menu is OFF
Unacceptable “Error Code” [CR]
9.11.17 CR_KEYDIS Command
Command “CR_KEYDIS”(CR)
Details
Get disablility status of RC/Projector keys (valid or invalid)
Response
Acceptable
“000_%a”[CR]
%a
“NONE” -------------------------- RC / Projector keys are valid
“RC” ------------------------------ RC keys are invalid
“KEY” ----------------------------- Projector keys are invalid
Unacceptable “Error Code” [CR]
9.11.18 CR_PJLOCKNOW Command
Command “CR_PJLOCKNOW” [CR]
Details
Get if PJ lock is actually in operation
Response
Acceptable
“000_%1[CR]
%1
“LOCK” ------------- PJ Lock is in operation. PJ Lock status is ON-1
or ON-2 on Menu, and PJ PIN CODE is not
entered so that projector is actually locked.
“FREE” ------------- PJ Lock is released. PJ Lock status is OFF, or,
status is ON-1 or ON-2 on Menu but PJ PIN
CODE is entered correctly so that PJ Lock is
released.
Unacceptable “Error Code” [CR]
9.11.19
CR_PJLOCKMENU Command
Command “CR_PJLOCKMENU” [CR]
Details
Get status of PJ Lock on Menu
Response
Acceptable
“000_%1[CR]
%1
“ON1” ------------- PJ Lock status is On-1
“ON2” ------------- PJ Lock status is On-2
“OFF” ------------- PJ Lock status is OFF
Unacceptable “Error Code” [CR]