PLC-XW200/250 Expand Serial Command Functional Specifications
50 / 64
9.8 Screen Status Read Command
9.8.1
CR_SCREEN Command
Command “CR_SCREEN”[CR]
Details
Get selected on-screen image size
Response
Acceptable
“000_%a”[CR]
%a
Input
is
PC
“NORMAL” --------------- Normal mode is selected
“TRUE” -------------------- True mode is selected
“WIDE” --------------------- Wide mode is selected
“FULL” --------------------- Full mode is selected
“CUSTOM” ---------------- Custom mode is selected
When the screen is set to D.Zoom, projector returns the previous
status (NORMAL )
Input
is
Video
“NORMAL” --------------- Normal mode is selected
“WIDE” -------------------- Wide is selected
“CUSTOM” --------------- Custom size is selected
Unacceptable
“Error Code”[CR] ------ When the command is invalid due to
condition such as Input source
9.8.2
CR_ KYSTNMODE Command
Command “CR_KYSTNMODE”[CR]
Details
Get setting status of Keystone Store Mode
Response
Acceptable
“000_%a”[CR]
%a
“STR” ---------------------- Store mode is “Store”
“RST” ---------------------- Store mode is “Reset”
Unacceptable “Error Code”[CR]
9.8.3
CR_VSCALE Command
Command “CR_VSCALE”[CR]
Details
Get setting status of Vertical Scale Store Mode
Response
Acceptable
“000_%1[CR]
%1
“-32” ~ “032”
Unacceptable “Error Code”[CR]
9.8.4
CR_VPOS Command
Command “CR_VPOS”[CR]
Details
Get setting status of Vertical Position Store Mode
Response
Acceptable
“000_%1”[CR]
%1
“-15” ~ “015”
Unacceptable “Error Code”[CR]
9.8.5
CR_HSCALE Command
Command “CR_HSCALE”[CR]
Details
Get setting status of Horizontal Scale Store Mode
Response
Acceptable
“000_%1”[CR]
%1
“-32” ~ “032”