PLC-XW200/250 Expand Serial Command Functional Specifications
49 / 64
9.7.7
CR_SYSLIST Command
Command “CR_SYSLIST”[CR]
Details
Get selectable System titles
Response
Acceptable
“000_%1_%2_..._%x” [CR]
%1
- When Input is PC-Analog
“XGA1” ------------ XGA1is selectable
“1080I ” ----------- 1080i is selectable
Projector does not return Auto,Mode1-5
When there is no signal, it returns Error Code “101”
-When Input is Y,Pb/Cb,Pr/Cr
Returns all the System titles on Menu including Auto
“AUTO” ------------ Auto is selectable
“1080I” ------------ 1080i is selectable
“1035I” ------------ 1035i is selectable
:
:
“575I” ------------ 575i is selectable
“480I” ------------ 480i is selectable
Projector does not return Error Code “101” evev if there is no
signal.
-When Input is Video, S-Video
Returns all the System titles on Menu including Auto
“AUTO” ---------Auto is selectable
“PAL” ------------ PAL is selectable
“SECAM” ------ SECAM is selectable
:
:
“PAL-N” --------- SECAM is selectable
Projector does not return Error Code “101” evev if there is no
signal.
Unacceptable ““Error Code”[CR]
9.7.8
CR_MODELIST Command
Command “CR_MODELIST”[CR]
Details
Get selectable Mode titles
Response
Acceptable
“000_%1_%2_..._%x” [CR]
%1
%2
:
%x
Returns Error code “101” when Input is other than PC-Analog
Returns Error code “101” when Input is PC-Analog but no signal
When Input is PC-Analog and signal is found, returns selectable
Mode among Mode1 – 5
“MODE1”
:
:
“MODE5
Unacceptable “Error Code”[CR]