PLC-XW200/250 Expand Serial Command Functional Specifications
53 / 64
9.9.5
CR_LAMPMSTS Command
Command “CR_LAMPSTS”[CR]
Details
Get Lighting status of lamp
Response
Acceptable
“000_%1”[CR]
%1
“n**** ” A number of * should be among 1-4.
First character shows how many lamps are incorporated in
projector. (1,2 or 4 )
Secound character shows follwing status in order of lamp number.
“I” Lamp is ON
“O” Lamp is OFF
“X” Lamp failure
e.g.
“1I”
・・・・・・・
1 Iamp model and Lamp is ON
“2IO
・・・・・・・
2 lamps model and No.1 Lamp is ON and No.2Lamp
is OFF
“4IOXI”
・・・・
4 lamps model and No.1,No.4 lamps are ON. No.2
lamp is OFF and No.3 model is failed.
Unacceptable “Error Code”[CR]
9.9.6
CR_PROJH Command
Command “CR_PROJH”[CR]
Details
Get total running time of Projector by hour (h)
Response
Acceptable
“000_%1”[CR]
%1
“0000000”~“0099999”
Unacceptable “Error Code”[CR]
9.9.7
CR_HMLAMP Command
Command “CR_HMLAMP”[CR]
Details
Get lamp number.
Response
Acceptable
“000_%1”[CR]
%1
“001”
Unacceptable “Error Code” [CR]
9.9.8
CR_LAMPLIFECONTRL Command
Command “CR_LAMPLIFECONTRL”[CR]
Details
Get setting status of Lamp life control.
Response
Acceptable
“000_%1”[CR]
%1
“MODE1”------------ Mode1 is selected
“MODE2”------------ Mode2 is selected
Unacceptable “Error Code” [CR]