background image

Cover can be flipped around 180 

degrees to hide LEDs from front 

straight-on view if desired.

Cover can be removed and painted to match 

color of wall. Do not paint the sides, top or 

bottom. Warranty will be voided.

Cover of MD2-RCA can easily be removed 

by pulling cover at the 2 side indents (1).
Unit can be securely screwed into wall 

outlet faceplate using either hole (2)  

indicated (screw is included).

1

2

1690 Corporate Circle, Petaluma, CA 94954  •  800-472-55555  •  707-283-5900  • Fax 707-283-5901  • www.panamax.com

INSTALLATION INSTRUCTIONS MD2-RCA

Bottom view 

of MD2-RCA

Top view of product

INS00878-A  1/10

CUSTOMER SUPPORT:

800-472-5555

OPTIONS FOR SECURITY MOUNTING & FRONT COVER FACEPLATE

FEATURES

LINES IN 

FROM

MD2-RCA

LEFT SIDE 

OUTLET

GROUND 

PLUG OUT

RIGHT 

SIDE 

OUTLET

GROUND 

PLUG 

DOWN

Side views of product

1. 

Turn off the equipment you are plugging into the MD2-RCA.

 

2

Plug the surge protector into the wall outlet. A red

 "Line Fault" 

light indicates 

an improperly wired outlet that must be checked by a qualified electrician. 

3. 

If the blue

 "Power On Protection OK"

 light is on, plug your equipment into 

the AC outlets on the surge protector.

The protection circuitry on the MD2-RCA and MD2-RCA MODULE only 
work if the signal lines are connected properly.

 

4.

 

Connecting signal lines to the MD2-RCA: The lines coming from the MD2-RCA 

MODULE plug into the “IN” jacks. Lines from the “OUT” jacks then connect to the 
equipment being protected.

4.5

 

Connecting signal lines to the MD2-RCA MODULE: The lines coming from the 

MD2-RCA plug into the “IN” jacks. Lines from the “OUT” jacks then connect to 
the source equipment in the rack.

5. 

To mount module to rack, slide zip ties through slots on back. Wrap and tie 

around leg on equipment rack. 

6. 

Turn the connected equipment ON and 

check for power and correct operation. 

Panamax surge protectors and the connected equipment must be indoors in a dry location and in the same building.  Do not install any 
Panamax product near heat emitting appliances such as a radiator or heat register.  Do not install this product where excessive 
moisture is present; for example, near a bathtub, sink, pool, basement floor, fish tank, etc.

It is not uncommon for a building to be improperly grounded.  In order to protect your equipment, and validate the warranty, Panamax 
products must be plugged into a properly grounded 3-wire outlet.  Additionally, building wiring and grounding must conform to 
applicable NEC (USA) or CEC (Canada) codes for the Panamax warranty to be valid.

Do not use 2-prong adapters with this product.  If an extension cord is required, use only Panamax #GEC1410.  If at any time your 
surge protector indicates a Line Fault, call your electrician to correct the building wiring.

POWER ON / 
PROTECTION OK- (blue) 
normally ON - indicates 
that the power is on, 
surge protector is 
functioning properly, 
and all connected 
equipment is protected.

LINE FAULT INDICATOR- 
(red)  - If lit red, indicates 
an improperly wired outlet.

AC outlets are turned 90 degrees from one 
another to accommodate different style  
plugs or transformers.

Properly Connecting Your Surge Protector

To completely protect your equipment from power surges, every wire leading into or out of the equipment you want to protect must be connected to the 
appropriate Panamax surge protector.  Damaging lightning and power surges can get into your system through any AC power or signal line (phone lines, 
grounding wires, coax cables, modem cables, etc.) connected to your electrical equipment.

The $100,000 Connected Equipment Protection Policy is invalid if any wire leading into or out of the equipment is not properly connected to the 
appropriate Panamax surge protector(s).  The surge protector must also be plugged into a properly wired and grounded outlet.  Please see the warranty 
for details or contact the Panamax Customer Relations department with questions. 

Overview

Make sure you have the right surge protector to protect your electronic equipment.  Panamax makes protectors for almost every type of electronic 
equipment.  Surge protectors that may look identical from the outside can be very different on the inside.  It is very important to use the surge protector 
designed for your application. Two-outlet surge protectors are not designed for use with systems having more than two AC powered components. 
Panamax offers a wide range of surge protectors designed for use with larger systems. If you have any questions about which product is best for your 
applications, please see our web site www.panamax.com or contact Panamax Customer Relations at 800-472-5555 (7:30 a.m. – 4:30 p.m.  PST).  

  Limited Lifetime Product 

 Warranty*  

$

100,000

 Limited Connected

Equipment Protection Policy*  

MD2-RCA

MD2-RCA MODULE

GROUND WIRE CONNECTED TO 

GROUND LUG ON BACK OF 

PANAMAX COMPONENT

IN RACK

LINES OUT TO

SOURCE 

       COMPONENT 

LINES IN FROM

MD2-RCA MODULE

LINES OUT TO EQUIPMENT

MD2-RCA

MODULE

MODULE MOUNTS 

VERTCAL OR HORIZONTAL 

POWER ON

PROTECTION OK

LINE

FAULT

TYPICAL INSTALLATION

 

IMPORTANT SAFETY POINTS

 

*See documentation on back side for details.

MD2-RCA

 PROPERLY GROUNDED 

AC OUTLET

 SIGNAL 

LINE IN

REMOTELY 

LOCATED 

POWERED 

SUBWOOFER

OR VIDEO

DISPLAY

AC LINE

  SIGNAL 
LINE OUT

GROUND WIRE CONNECTED

TO PANAMAX COMPONENT

GROUND LUG 

EQUIPMENT 

RACK

IN                  IN                  IN

OUT              OUT              OUT

IN                  IN                  IN

OUT              OUT              OUT

SIGNAL 

LINE IN 

MD2-RCA MODULE 

STRAPPED TO RACK LEG WITH ZIP TIES (INCLUDED)  

SIGNAL LINE OUT

TO SOURCE

COMPONENT 

CONNECTED TO

SOURCE COMPONENT

 

AC LINE

Отзывы: