PLV-HD2000 Basic Serial Command Functional Specifications
9/24
6.5 POWER ON Command
COMMAND “C00”
[CR]
Detail
Power ON
When already Power is ON, no operation is started.
When sending this command during Countdown in process, Countdown is
terminated.
Acceptable [ACK]
[CR]
Response
Unacceptable “?”
[CR]
6.6 POWER OFF Command
(Immediate POWER OFF)
COMMAND
“C01” [CR]
Detail
Power OFF (Standby)
This command immediately executes Power OFF operation without displaying
“Power OFF” message, unlike the operation with ON-OFF button of the projector
or remote control.
Acceptable [ACK]
[CR]
Response
Unacceptable “?”
[CR]
6.7 INPUT 1 Command
COMMAND
“C05” [CR]
Detail
Select INPUT1.
Note) When there is no board inserted to INPUT1, it is not executed.
Acceptable [ACK]
[CR]
Response
Unacceptable “?”
[CR]
6.8 INPUT 2 Command
COMMAND
“C06” [CR]
Detail
Select INPUT2.
Note) When there is no board inserted to INPUT2, it is not executed.
Acceptable [ACK]
[CR]
Response
Unacceptable “?”
[CR]
6.9 INPUT 3 Command
COMMAND
“C07” [CR]
Detail
Select INPUT3
Note) When there is no board inserted to INPUT3, it is not executed.
Acceptable [ACK]
[CR]
Response
Unacceptable “?”
[CR]