7.10 PC Type Read Command
COMMAND “CR9”
[CR]
Detail
Get currently projected PC mode
Acceptable “%1”
[CR]
%1
“Standby” - - - - - - - - - - - - - - - - - - - - - Standby
“AV_Mode” - - - - - - - - - - - - - - - - - - - - AV Mode
Current table such as “UXGA_1” - - - - - PC Mode
“Mode1~20” - - - - - - - - - - - - - - - - - - - Mode1~20
“Go_PC_adj.” - - - - - - - - - - - - - - - - - - Auto
“No_signal”. - - - - - - - - - - - - - - - - - - - No signal
Response
Unacceptable “?” [CR]
7.11 Status 2 Read Command
COMMAND “CRA”
[CR]
Detail
Get the operating status of Video Mute
Acceptable “%1”
[CR]
%1
Indicates setting status of No show.
+ +
No Show ON/OFF
(ON =1, OFF =0)
There is a signal/ no signal
(No signal =1, Signal =0)
e.g.
Normal operation ----- 00
No show is on --------- 01
No signal --------------- 80/81
When it is in Standby mode or during Cooling Down operation, it
returns “FF”.
Response