PLV-HD2000 Basic Serial Command Functional Specifications
17/24
・
“10” [CR]
Status: Power Failure
When the power supply voltage inside the projector reaches abnormal level, the status
moves to Power OFF automatically. The projector returns “10” [CR], which indicates it
has moved to Power OFF status due to power failure. Unlike Cooling Down status, Fan
also stops in this case. This status continues for about 90 seconds and moved to
Stand-by.
・
“28” [CR]
Status: Cooling Down in process due to Abnormal Temperature
When the internal temperature increases abnormally, it automatically starts Cooling
Down operation. Response for this status is “28” [CR].
Even if the temperature decreases during this process, Cooling Down is executed for
given time and it moves to Standby mode.
・
“02” [CR]
Status: RS-232C Commands can not be accepted.
When receiving this response, re-send the Status Read Command.
・
“24” [CR]
Status: Power Management / Cooling Down in process
When Power management function is set to ON in setting menu and no signal status
continues for 5 minutes, projector turns off the lamp(s) and enters the Power
Management/Cooling down operation. During this time, Functional Execution
Commands are invalid.
The status moves to power saved mode after the given time of
Power Management / Cooling Down operation has been executed.
Status: No signal Power Management / Cooling Down Power Management
Response:
“00”
“24”
“04”
Time set by power management timer with no signal
After about 90 sec.
・
“04” [CR]
Status: Power Management
This indicates it has moved to Power Management status as Power management
function is set to ON.