Control of W-2WAY ECO-i SYSTEM
4. System Controller
D: ON button
This button is for turning the selected air conditioner on.
E: OFF button
This button is for turning the selected air conditioner off.
F: Operation lamp
This lamp lights when the unit is turned on.
G: MODE button
Use this button to select one of the following 5 operations:
(AUTO)
: Used to automatically set cooling or heating operation.
Only for heat pump type
(Temperature range: 17 to 27°C)
(HEAT)
: Used for normal heating operation.
Only for heat pump type
(Temperature range: 16 to 26°C)
(DRY)
: Used for dehumidifying without changing the room temperature.
(Temperature range: 18 to 30°C)
(COOL)
: Used for normal cooling operation.
(Temperature range: 18 to 30°C)
(FAN)
: Used to run the fan only, without heating or cooling operation.
NOTE
When the
indication is displayed, you cannot change the mode from
and
or
to
or
and . To change the mode, turn off all units once then select the
mode again.
H: Temperature setting
buttons
: Press this button to increase the temperature setting.
: Press this button to decrease the temperature setting.
I: FAN SPEED button
(AUTO)
: The air conditioner automatically decides the fan speed.
(HI)
: High fan speed
(MED)
: Medium fan speed
(LO)
: Low fan speed
J: FLAP button
1. Use this button to set the airflow direction to a specific angle.
The airflow direction is displayed on the remote control unit.
Operation mode
(COOL) or (DRY)
(HEAT) or
(FAN)
(AUTO)
Cooling mode:
Heating mode:
Number of airflow direction settings
3
5
3
5
CAUTION
In the Cool mode and Dry mode, when the flaps are set in a
downward position, condensation may form and drip around the
vent.
Do not move the flap with your hands.
NOTE
This function is available only for models X, T and LD.
(
)
2. Use this button to make the airflow direction sweep up and down automatically.
Press this button several times until the (
) symbol appears on the display.
NOTE
This function is available only for models X, K, T and LD.
NOTE
1) The flap setting can be performed only for units that have no remote controllers.
2) In the ALL or ZONE mode, no flap setting can be performed. If necessary, you
should select the GR mode and use the FLAP button.
Содержание ECO G SPW-GU055XH
Страница 2: ...i ...
Страница 3: ...ii ...
Страница 146: ......
Страница 198: ......
Страница 200: ...6 2 Electrical Data 1 2 3 4 5 6 7 8 1 Outdoor Unit 1 Electric Wiring Diagram SPW C0705DXHN8 ...
Страница 201: ...6 3 Electrical Data 1 2 3 4 5 6 7 8 1 Outdoor Unit Schematic Diagram SPW C0705DXHN8 ...
Страница 202: ...6 4 Electrical Data 1 2 3 4 5 6 7 8 1 Outdoor Unit 2 Electric Wiring Diagram SPW C0905 C1155DXHN8 ...
Страница 203: ...6 5 Electrical Data 1 2 3 4 5 6 7 8 1 Outdoor Unit Schematic Diagram SPW C0905 C1155DXHN8 ...
Страница 204: ...6 6 Electrical Data 1 2 3 4 5 6 7 8 1 Outdoor Unit 3 Electric Wiring Diagram SPW C1305 C1405DXHN8 ...
Страница 205: ...6 7 Electrical Data 1 2 3 4 5 6 7 8 1 Outdoor Unit Schematic Diagram SPW C1305 C1405DXHN8 ...
Страница 206: ...6 8 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit 1 Electric Wiring Diagram SPW GU055 075 105XH ...
Страница 207: ...6 9 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit 2 Schematic Diagram SPW GU055 075 105XH ...
Страница 208: ......
Страница 242: ......