SY75C Excavator OMM
Maintenance Procedures
SANY
Operation and Maintenance Manual — 0220
5-81
TABLE OF
CON
T
ENT
S
INT
R
ODUCT
ION
SA
FETY
MA
C
H
INE
CONTROLS
MA
C
H
INE
OPERA
T
ION
MAINTENAN
C
E
SPECIFICA
T
IONS
OP
T
ION
AL
EQUIPMENT
Swing Bearing Bolts - Check
1. Locate and inspect swing bearing mounting bolts (a) for
presence and physical damage of any kind.
2. Turn the engine on, turn the cab 90° to the right.
3. Turn the engine off.
4. Repeat step 1 through 3 until you have inspected all of
the bolts.
Swing Drive - Check
1. Locate and inspect swing drive (a) for physical damage
of any kind.
2. Remove check/fill plug (b) from the swing gearbox and
note the oil level.
NOTE:
The oil level should be within 1/4 in. (6 mm) of
the top of the inspection hole.
3. Add oil as needed.
4. Reinstall the plug.
NOTICE!
Do not overfill. This could result in machine
damage and improper machine operation.