SY75C Excavator OMM
Maintenance Procedures
SANY
Operation and Maintenance Manual — 0220
5-63
TABLE OF
CON
T
ENT
S
INT
R
ODUCT
ION
SA
FETY
MA
C
H
INE
CONTROLS
MA
C
H
INE
OPERA
T
ION
MAINTENAN
C
E
SPECIFICA
T
IONS
OP
T
ION
AL
EQUIPMENT
Hydraulic Pilot Line Filter Element - Replace
NOTE:
Perform this procedure after the first month (250 hours) and then every 1,000 service hours or at least
once each year, whichever occurs first.
NOTE:
Ensure that the machine is on flat, level ground before proceeding.
1. Locate hydraulic pilot line filter (a) behind the right rear door
2. Loosen lower housing (b).
3. Place an appropriate sized container underneath the
filter lower housing.
4. Remove filter lower housing (b).
NOTICE!
Dispose of the drained oil in accordance with
local environmental regulations. Failure to do so
could result in damage to the environment.
Fig. 5-96
a
Fig. 5-97
b