Maintenance Procedures
SY75C Excavator OMM
5-32
Operation and Maintenance Manual — 0220
SANY
Engine Coolant - Change.
1. Swing upper structure (a) to position the drain valve
beneath the radiator for better access.
2. Shut down the engine.
3. Open engine cover (b).
DANGER!
Inhaling or ingesting coolant is toxic. If not avoided, this will result in death or injury.
CAUTION!
Do not remove the filler cap while the engine is hot. Engine coolant is under pressure when
hot and will spurt out. Always wait for the engine to cool before removing the filler cap. Failure
to follow this warning will result in creating a hazardous situation which could result in minor
or moderate injury.
Fig. 5-29
a
Fig. 5-30
b