
Maintenance Procedures
SY75C Excavator OMM
5-30
Operation and Maintenance Manual — 0220
SANY
4. Open air filter housing (c) and remove primary air filter
(d).
5. Inspect the air filter for damage, dampness or dust.
NOTE:
If you find any damage, moisture or dust in the
filter replace it.
6. Clean the inside of air filter housing (e) with a clean
cloth before you replace the primary air filter.
NOTICE!
Do not attempt to clean the air filter. Failure to
replace a damaged, damp or clogged air filter
could result in machine damage and improper
machine operation.
Fig. 5-26
c
d
Fig. 5-27
e
Содержание SY75
Страница 1: ...service sanyamerica com SANY Part Number SSY005081688 SY75 Excavator Operation and Maintenance Manual ...
Страница 2: ......
Страница 70: ...Monitor SY75C Excavator OMM 3 32 Operation and Maintenance Manual 0220 SANY This Page Intentionally Left Blank ...
Страница 223: ...This Page Intentionally Left Blank ...