TELEMETRY MENU
TELEMETRY
LOGGER
ALERT SETTING
TELEMETRY SETTING
●
A menu for setting Telemetry-related LOGGER, ALERT SETTING, TELEMETRY SETTING.
●
To use the Telemetry, you can check with a compatible device such as SUPER VORTEX series.
●
With Telemetry, you can check the data of 2 line of temperature, battery voltage and number of rotations
with the transmitter.
・
LOGGER:Check 2 line of temperature, battery voltage
and number of rotations
・
ALERT SETTING:Alert by setting temperature and battery voltage
・
TELEMETRY SETTING:Various settings of Telemetry features
●
Transmitter enables to record 2 temperatures (T1/T2) as battery, engine, and motor receiver voltage,
engine or motor rotation number (PRM) with compatible receiver and Super Vortex series.
●
Record (Log) setting can be set LOG STEP on the TELEMETRY SETTING (p.42).
Log data interval is 0.1 ~ 45.9 seconds.
●
Record (Log) can be 120 STEP (Min 12 seconds ~ Max 90 minutes).
●
Logger working can be started by holding enter on each [LOGGER] display (T1/T2/VOLT/RPM) or
assinged switch.
1) Select [TELEMETRY] with up and down key. Determine with enter.
2) Select [LOGGER] with up and down key. Determine with enter.
3) Seletct data for display [T1/T2/VOLT/RPM(RP)] with
up and down key. Determine with enter.
Check log data with up and down key.
●
Alert setting is alerting by setting temperature and voltage. Also, transmitter blue LED will flash by setting
telemetry data.
1) Select [TELEMETRY] with up and down key. Determine with enter.
2) Select [ALERT SETTING] with up and down key.
Determine with enter.
3) T1 ALERT SETTING
Select [T1 ALERT] with up and down key. Determine with enter.
○
Setting Range: 0
~
150
℃
(32
~
302
℉
)
○
Default: 100
℃
(212
℉
)
4) T2 ALERT SETTING
Select [T2 ALERT] with up and down key. Determine with enter.
○
Setting Range: 0
~
150
℃
(32
~
302
℉
)
○
Default: 100
℃
(212
℉
)
5) VOLT ALERT Setting
Select [VOLT ALERT] with up and down key. Determine with enter.
○
Setting Range: 3.0V ~ 9.0V
○
Default: 3.8V
5) HOLD TIME Setting
*Sudden throttle work might be caused to instant voltage drop
and it might lead unnessesry alert. In this situation, the HOLD TIME
setting can make time to prevent from the unnessesary alert
and provide stable alert for the unusual situation.
○
Setting Range: 0.0~5.0 sec
○
Default: 1.0 sec
●
Set each feature of Telemetry.
1) Select [TELEMETRY] with up and down key. Determine with enter.
2) Select [ALERT SETTING] with up and down key.
Determine with enter.
3) TELEMETRY ON/OFF SETTING
Select [ON/OFF] with up and down key. Determine with enter.
○
Setting Range: ON/OFF
○
Default: ON
4) LOG STEP SETTING
Select [LOG STEP] with up and down key. Determine with enter.
○
Setting Range: 00.1 ~ 45.9s
○
Default: 00.1s
5) T1/T2 UNIT SETTING (Temperature unit setting)
Select [T1/T2 UNIT] with up and down key. Determine with enter.
○
Setting Range:
℃
/
℉
○
Default:
℃
6) RPM RATIO SETTING
*When setting RATIO RPM sensor in the subtracted position,
you can display the number of rotations of the motor and
engine after back calculation with RATIO setting.
○
Setting Range: 00.001
~
64.999
○
Default: 01.000