background image

4

Instruction Manual for Sanuvair

®

 S300

1-888-726-8869

www.sanuvox.com

SETUP & INSTALLATION

What you will need

Utility knife, scissors, wire cutters, air inlet grid (optional), air outlet grid (optional), suitable wall plugs and screws (as needed), 

screwdriver, pliers, masking tape, felt pen, two 8" collars (optional) and suspensions rods (optional).

 CAUTION: Handle your product with care to avoid breaking parts. Make sure you have a free and safe space to unpack, 

install and setup your product. Confirm you have access to the necessary power source for the product requirements (see unit 

or system label). If you have any questions regarding the installation instructions, call SANUVOX at 1-888-726-8869.

What’s included

The SANUVAIR

®

 S300, a MERV9 prefilter, a HEPA filter, a UV lamp, the access door for the lamp and ballast (white metal plate) 

and a basic installation kit.

The installation kit includes: a pair of cotton gloves, a paper template for duct installation, 17" mounting angles (2), a 3-prong 

power cord (6’), self-adhesive foam tape for sealing openings (8’) and self tapping 8/32 x 1/2 screws for the front plate (6).

Special considerations for integrated system installation

• 

Verify clearance on the ductwork to mount the unity using the Forced Air / Heating Cooling system;

• 

Respect minimum clearance requirement for maintenance and service;

• 

Electrical power requirements;

• 

Interaction between the HEPA / UV air purifier unit and other mechanical devices.

Step by Step Setup | UV Lamp & Filters

1. 

Open the filters and motor access door

 of your S300 unit: this is the 

large square door closed by the big black clamp.

2. 

Check the filters (2): 

If they are covered with plastic wrap, be sure to 

unpack them before proceeding.

 

NOTE: 

Make sure to install filter(s) according to air flow direction for 

maximum performance. 

3.  Under the HEPA filter is the cardboard sleeve containing the UV lamp. 

Carefully slide the UV lamp out from the cardboard sleeve.

 Be sure 

to wear the cotton gloves (included) ensuring the lamp is free from 

fingerprints.

 

NOTE: Fingerprints on the lamp will negatively impact the UV output of 

the lamp.

STEP 1

STEP 2

STEP 3

Содержание S300

Страница 1: ...bels attached to the UV unit or system and all other safety precautions considered as best practices in the HVAC industry if applicable 9 When applicable local regulation may comprise more restrictive installation and or certification requirements The aforementioned requirements prevail on those of this document and the installer agree to conform to these at his own expense 10 Follow all the safet...

Страница 2: ...nstallations 6 Step by Step Installation Stand Alone 7 Step by Step Installation Duct Mounted Bypass 8 Step by Step Installation Added Ducts 9 OPERATION 10 How to Operate your Product 10 How to Select Speed 10 How to Read the LED Status Display 10 MAINTENANCE 11 How to Replace Lamp 11 Step by Step Lamp Replacement 11 How to Replace Filters 12 Step by Step Filter Replacement 12 How to Clean your Pr...

Страница 3: ...net enclosure The ventilator pulls air through the prefilter and pushes the same air through the HEPA filter which helps reduce 99 97 of particles that are 0 3 microns or larger in size A Lamp Ballast Access Door Plate must be installed once lamp setup are done B LED Status Display C Filters and Motor Access Door D Door Latch E Prefilter F Motor G Door Interlock Switch H Speed Selection Switch I H...

Страница 4: ...7 mounting angles 2 a 3 prong power cord 6 self adhesive foam tape for sealing openings 8 and self tapping 8 32 x 1 2 screws for the front plate 6 Special considerations for integrated system installation Verify clearance on the ductwork to mount the unity using the Forced Air Heating Cooling system Respect minimum clearance requirement for maintenance and service Electrical power requirements Int...

Страница 5: ...he holes The connector will fit into position NOTE Too much force applied from the opposite end cap may break the lamp 6 Then slide the porcelain tip through the retention clamp NOTE Make sure the lamp is horizontal in this section and not touching the metal walls STEP 7 STEP 8 7 Take the access door for the lamp and ballast from the supplied accessories and position it over the rectangular openin...

Страница 6: ...he air inlets and outlets duct mounted bypass OR with added ducts using 8 collars In a commercial setting the S300 unit can be positioned horizontally or vertically on a wall or on a ceiling with angles and suspension rods In a residential environment a ceiling installation with suspension rods is NOT recommended Stand Alone attic Stand Alone basement Duct Mounted Bypass Added Ducts ...

Страница 7: ... of the unit top by using the screws already in place Then secure the second mounting angle along the rear edge at the bottom of the unit STEP 1 STEP 2 3 Secure the unit to the wall vertically or horizontally or to the ceiling using suitable wall plugs and screws not included Make sure you have a power outlet nearby to plug the unit into CAUTION Your S300 unit is bulky Make sure that there are alw...

Страница 8: ...et and outlet vents that you have made at the rear of the unit 4 Use the self adhesive foam tape and stick it around the outline of the two back openings to ensure their tightness when the unit is attached to the pipe You will probably need to cut the tape into pieces to form the two tape rectangles 7 Install the unit vertically on the duct aligning the openings Secure the unit in place with the s...

Страница 9: ...it 5 Install your 8 rigid in aluminum or galvanized or aluminized flexible pipes Your new SANUVAIR S300 is now ready to operate STEP 3 STEP 4 STEP 5 Step by Step Installation Added Ducts 1 Using wire cutters cut the small metal pieces supporting the pre cut 8 round opening at the top of the unit and do the same with the one undererneath You will need to use a blade to cut the paper on top as well ...

Страница 10: ...cabinet hinges by holding the top part of the door with one hand and gently tapping on the bottom edge of the door with your hand to release the door from its hinges LED Status Display Door Interlock Switch Inside the unit Speed Selection Switch Ventilation speed maximum 300 CFM Ventilation speed normal 220 CFM How to Select Speed The Sanuvair S300 features two speeds of operation The speed select...

Страница 11: ... the unit or system TURN OFF AND DISCONNECT the unit or system from all power sources 2 Prepare the new lamp Remove the contents from packaging Only after you have visually inspected the UV lamp should you break the security seal on the underside of the cardboard sleeve Be sure to wear the cotton gloves included guaranteeing a clean lamp free from fingerprints Fingerprints on the lamp will negativ...

Страница 12: ...ter Replacement 1 Open the filters and motor access door at the front of the unit Opening the latch on the right side of the unit will permit the door to swing open If necessary the door can be removed from the cabinet hinges by holding the top part of the door with one hand and gently tapping on the bottom edge of the door with your hand to release the door from its hinges 2 After opening the uni...

Страница 13: ...c storage ELECTRICAL RATINGS POWER CONSUMPTION AVAILABLE VOLTAGE The product is rated at 120 240VAC 50 60Hz and 48W See product label to confirm power consumption of your specific unit or system NOTE IF YOU EXPERIENCE A PROBLEM PLEASE CONTACT CUSTOMER SERVICE FIRST OR SEE YOUR WARRANTY DO NOT RETURN THE PRODUCT TO THE ORIGINAL PLACE OF PURCHASE DO NOT ATTEMPT TO OPEN THE PRODUCT OR TAMPER WITH ITS...

Страница 14: ... found to be defective in material or workmanship C This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual D This warranty does not cover the filters prefilters or other accessories if included except for material or workmanship defects Call us toll free at 1 888 726 8869 or email info sanuvox com Please ...

Отзывы: