User manual SNC-670ID/W
_________________________________________________________________________________
- 14 -
1.11. Diagnosis
When the camera is switched on, the DIAGNOSIS menu appears. The following notification is
displayed:
Pan origin test
After the panning test, the pan function is set to zero.
Tilt origin test
After the tilting test, the tilt function iss et to zero.
TX connection test
60 seconds countdown for TX connection test. The camera has to receive a signal from a
controller or a video for a duration of 60 seconds. Once the correct signal is received, the TX
connection test says "OK“.
If the notification „Not Tested“ is displayed on the monitor:
the camera didn’t receive any signal
the camera hasn’t received a readable signal
protocol, Baud rate and RS-485 connector should be checked.
Camera communication test
The camera communication test is initialised automatically. Before the installation these 4
tests should be completed with “OK”.
Once all tests are okay, the following notifications appear on the monitor: „NOW EEPROM
CHECKING“ and „ALL DATA INITIALIZING“. The camera is now ready to be used.
CAMERA ID : 001
BAUD RATE : 2400 BPS
WAITING………
PAN ORIGIN
TILT ORIGIN
TX CONNECTION TEST
OK
CAMERA COMM
TEST OK