(2) Connection of the vibration sensor
Connect the vibration sensor input cable (P4 cord) of the Controller to the Vibration Sensor
(KS-3).
※
1.
The vibration sensor input cable (P4 cord) is connected to the on-board connector. To
replace the input cable, replace it by a dedicated cable at the on-board connector.
Confirm the power-OFF status, and then detach the operation panel.
Note that the operation panel is connected to the controller main body with a connecting
wire. When attaching/detaching the operation panel, carefully watch out for the
connecting wire to avoid disconnection or pinching.
※
2. Limit the total length of the cable between the controller and the feeder (vibration sensor)
to 4m.
To extend the cable, be sure to use the dedicated cable of our make.
In wiring each cable, detach the wiring from the power cable.
4) Overflow sensor [in2 input] connection
Connect the overflow sensor to the terminal of the overflow sensor input cable (P3 cord).
The connection enabled sensor can use the NPN open collector output.
(The PNP open collector output sensor cannot be connected.)
※
1. The input cable (P3 cord) of the overflow sensor is connected to the terminal block [in2
Input].
※
2. When the overflow sensor is not connected, set as
“
Parameter No. 07=Lo.
”
※
3. The power outlet of the Controller is of 24VDC, 160mA. Watch out for the total
consumption current of the overflow sensor, solenoid valve, etc. to ensure that it will not
exceed the power outlet capacity.
[Terminal connector signal name of P3 cord]
Internal circuit
Red [24V terminal No. A0]
–
Sensor brown wire
Black [0V terminal No. A6]
–
Sensor blue wire
White [Signal terminal No. A2]
–
Sensor black wire
Sensor: Black
Sensor: Blue
Sensor: Brown