Initial Startup Preparation
1. Connect the regulator to an approved CO2 cylinder and
connect to the CO2 port on the "smart coupler".
2. Turn the "smart coupler" to the "OFF" position.
3. Set the CO2 regulator to 12-13 psig.
4. Prepare a 5 gallon container of brewery approved beer line
cleaning solution and connect to the "smart coupler".
5. Turn the coupler lever to the "CLEAN" position.
6. Fill the freezing cylinder until the amber light goes out.
7. Lift up on the Pressure Relief Plug (Fig. 4) to vent air from
the freezing cylinder. When solution discharges from the
bottom of the Pressure Relief Plug, close by pushing
downward on the plug.
8. When the amber light goes out again, turn the "Auto/
Cleanout" switch to the "CLEAN" position and allow the
machine to run for approximately 3 minutes.
9. Turn the machine to "OFF" and drain cleaning solution by
opening spigot and Pressure Relief Plug. Close plunger
and plug when machine is drained.
10. Repeat steps 4 through 9 using fresh potable water and
drain.
1. With machine in "OFF" position, connect keg of product and fill cylinder until amber light goes off.
2. Allow any foam to settle and vent barrel by lifting up on the pressure relief plug. Close Pressure Relief Plug.
3. Turn "Auto/Cleanout" to the "AUTO" position.
4. When the machine cycles off, draw a sample of product and check for proper consistency. Repeat this step two
times.
5. If the product is too soft or two stiff, refer to the section on consistency adjustment.
Operation
Fig. 4
Pressure Relief Plug
Disassembly and Cleaning
CONSULT YOUR LOCAL HEALTH AGENCY FOR LOCAL CLEANING AND SANITIZING REQUIREMENTS.
This unit does not come pre-sanitized from the factory. Before serving product, the dispenser must be disassembled,
cleaned, lubricated, and sanitized. Please be aware that these instructions are general guidelines. Cleaning and sanitizing
procedures must conform to local Health Authority requirements.
Emptying Machine
Prior to the disassembly and cleaning of parts, the machine must be emptied of product. Use the following
Procedures. If this is first time operation, disregard these steps.
1. Set the Auto/Clean switch to the
“CLEANOUT”
position and dispense all product from the freezing cylinder by
pulling downward on the spigot handle to empty the machine.
2. Set the Auto/Clean switch to the
“OFF”
(center) position. Close the spigot handle before proceeding to cleaning.
DO NOT INSERT ANY OBJECTS OR TOOLS FRONT PLATE DISPENSING HOLE WHILE THE MACHINE IS
RUNNING. DAMAGE TO THE MACHINE OR PERSONAL INJURY MAY RESULT
DISASSEMBLY and CLEANING
PAGE 3