background image

 
 

360 Herndon Parkway 

 Suite 

1400 

 

Herndon, VA 20170 

 http://www.rheintech.com 

 

SanDisk Corporation 

 

 

 

 

 

 

 

 

           Page 17 of 17 

DoC Report 
2006137 
04/27/07 

MANUFACTURER’S EQUIPMENT FILE CHECKLIST (PER FCC RULES 

§

2.1075) 

 

This checklist shall be used by the manufacturer to verify the correct filing per FCC 2.1075 Retention of records 
for products produced and marketed. 

 

PRODUCT 

MODEL(s): 

     Records 

Verified 

By: 

 

SanDisk SSD SATA 5000 2.5” 

A record of the original design drawings and specifications. 

 

A record of all changes that have been made that would affect continued compliance 
with the authorized unit (e.g., any changes which would require a Class I or Class II 
permissive change). 

 

A record of the procedures used for production inspection and testing (if tests were 
performed) to ensure ongoing conformance. 

 

A record of the measurements made on an appropriate (NVLAP-accredited) test site 
that demonstrates compliance.  The record shall contain: 

 

 

(i) The actual date or dates testing was performed; 

 

  (ii) The name of the test laboratory, or individual performing the testing.  (The 

Commission may request additional information regarding the test site, the test 
equipment or the qualifications of the Test laboratory from the client. or individual 
performing the tests); 

 

 

(iii) A description of how the device was actually tested, identifying the measurement 
procedure and test equipment that was used contained in the test report 

 

  (iv) A description of the equipment under test (EUT) and support equipment 

connected to, or installed within the EUT 

 

 

(v) The identification of the EUT and support equipment by trade name and model 
number and, if appropriate, by FCC identifier and serial number; 

 

 

(vi) The types and lengths of connecting cables used and how they were arranged 
or moved during testing; 

 

 

(vii) At least two photographs showing the test set-up for the highest line conducted 
emission and showing the test set-up for the highest radiated emission.  These 
photographs must be focused originals which show enough detail to confirm other 
information contained in the test report; 

 

  (viii) A description of any modifications made to the EUT Client, or individual to 

achieve compliance with the regulations; 

 

 

(ix) All of the data required to show compliance with the appropriate regulations; 

 

 

(x) The signature of the individual responsible for testing the product along with the 
name and signature of an official of the responsible party, as designated in 

§

2.909; 

 

 

(xi) A copy of the compliance information (i.e., the DoC), as described in 

§

2.1077, 

required to be provided with the equipment as follows: 

 

(a) 

  Identification of the product (name and model number); 

 

(b) 

 The unique model name and FCC DoC logo information as specified in 

§

15.19(b)(1) and 

§

15.105, that the product complies with Part 15 of the FCC 

Rules; 

 

(c) 

  Identification, by name, and address of the responsible party. 

 

 

 

Содержание CompactFlash 5000

Страница 1: ...rporation 7 Atir Yeda Street Kfar Saba Israel Phone 972 9 7644908 Device Under Test SanDisk SSD SATA 5000 2 5 Document Number 2007160 Reference Number QRTL07 033 This report may not be reproduced exce...

Страница 2: ...g FCC Class B Compliance Standard s to which device was tested STANDARDS SPECIFIC TESTS APPLICABILITY Tested Not Tested CFR47 Parts 15 109 and 15 107 Radiated and Conducted Emissions Test Engineer Jon...

Страница 3: ...IGURATION OF TESTED SYSTEM 7 3 PRODUCT LABELLING INFORMATION TO THE USER 8 3 1 DOC LABEL ON DEVICE 8 3 2 DOC STATEMENT IN USER S MANUAL 8 3 3 LOCATION OF LABEL ON EUT 8 4 CONDUCTED EMISSIONS 9 4 1 SIT...

Страница 4: ...te 1400 Herndon Va 20170 Complete description and site attenuation measurement data has been placed on file with the Federal Communications Commission The power line conducted emission measurements we...

Страница 5: ...sis o Operating shock 1 500G 0 5msec half sine o Operating vibration 2 17G 7 500 Hz o Operating temperature 0 C to 70 C o Non operating temperature and storage 55 C to 95 C o Operating temperature 0 C...

Страница 6: ...on RTL Bar Code Equipment Arrival Date Laptop PC Dell Latitude D620 PP18L N A DoC Unshielded Power N A 4 10 2007 Laptop AC Adapter Dell LA65NS0 00 CN 0DF263 71615682 2ED4 N A Unshielded 017737 4 10 20...

Страница 7: ...1400 Herndon VA 20170 http www rheintech com SanDisk Corporation Page 7 of 17 DoC Report 2006137 04 27 07 2 5 CONFIGURATION OF TESTED SYSTEM Laptop PC with SanDisk SSD SATA 5000 USB Termination Monito...

Страница 8: ...pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate...

Страница 9: ...ne and electrically connected to the peripheral LISN powers the EUT host peripherals The spectrum analyzer was connected to the A C line through an isolation transformer The 50 ohm output of the EUT L...

Страница 10: ...9 56 0 19 1 46 0 9 1 Pass 15 070 Pk 25 2 2 3 27 5 60 0 32 5 50 0 22 5 Pass 17 640 Pk 28 2 2 5 30 7 60 0 29 3 50 0 19 3 Pass 25 100 Pk 29 4 2 7 32 1 60 0 27 9 50 0 17 9 Pass Phase Conductor Temperatur...

Страница 11: ...360 Herndon Parkway Suite 1400 Herndon VA 20170 http www rheintech com SanDisk Corporation Page 11 of 17 DoC Report 2006137 04 27 07 4 3 CONDUCTED TEST PHOTOGRAPHS...

Страница 12: ...ency the EUT was rotated 360 and the antenna was raised and lowered from 1 to 4 meters in order to determine the emission s maximum level Measurements were taken using both horizontal and vertical ant...

Страница 13: ...orrection Factor SCF used in the above equation is determined empirically and is expressed in the following equation SCF dB m PG dB AF dB m CL dB SCF Site Correction Factor PG Pre amplifier Gain AF An...

Страница 14: ...1 0 42 2 19 4 22 8 30 0 7 2 Pass 200 000 Qp V 190 1 0 35 3 19 0 16 3 30 0 13 7 Pass 225 000 Qp V 290 1 0 32 7 18 5 14 2 30 0 15 8 Pass 250 000 Qp H 160 4 0 44 2 15 5 28 7 37 0 8 3 Pass 369 340 Qp H 19...

Страница 15: ...360 Herndon Parkway Suite 1400 Herndon VA 20170 http www rheintech com SanDisk Corporation Page 15 of 17 DoC Report 2006137 04 27 07 5 4 RADIATED TEST PHOTOGRAPHS...

Страница 16: ...Solar 8130 947306 900729 N A 16A LISN AFJ International LS16 110VAC 16010020080 901083 4 4 2008 16A LISN AFJ International LS16 110VAC 16010020081 901082 1 6 2008 Current Probe Telecom conducted Fisc...

Страница 17: ...g the measurement procedure and test equipment that was used contained in the test report iv A description of the equipment under test EUT and support equipment connected to or installed within the EU...

Отзывы: