manualshive.com logo in svg
background image

TY-JS-220308-001

4

Notice

In order to ensure your personal safety and avoid property loss, you must pay attention to

this manual, but not limited to the following warning notices. General electric knowledge

and safety standards should also be followed.

DANGER

Failure to take safety measures will result in death or serious

personal injury.

Notice

Operation Guideline

The Operation should be

carried out by professional

technicians

Handling, installation of pipes, electrical, operation,
maintenance, overhaul and other operations must be
carried out by personnel with professional knowledge.

It is forbidden to be used

beyond the range of

specification

It is forbidden to use the equipment beyond the range of
manual specifications in order to avoid equipment
damage, injury, fire, electric shock and other major
accidents.

It is forbidden to be used in

the explosive environment

It cannot be installed in dangerous places with
flammable gas.

Electrical connection

a) The power supply must conform to the standard
indicated in the nameplate or the manual;
b) Use the standard cable, and select the standard wire
diameter;
c) The grounding wire must be installed and the
connection must be reliable; otherwise, it will cause an
electric shock or fire.

It is forbidden to operate the

equipment without a cover

There are live parts inside the machine. It is forbidden to
operate without a cover, as there is a risk of electric
shock.

Water-proof

Do not allow the equipment to be drenched or immersed
in water, otherwise there may be a risk of short circuit
and electric shock.

Maintenance and repair

The operation must be carried out after 3 minutes of
cutting off the power supply, because the high-voltage
charging part in the equipment is not discharged within 3
minutes. Working in a live state or working immediately
after shutdown will cause the risk of electric shock.

Danger

High Voltage

Contact with live parts can cause serious personal injury
or death.

Danger

Hot Surface

The human body or the heat-labile articles must keep
away from this high temperature area. Otherwise, it will
cause personal injury or property loss.

Содержание CW-5000 Series

Страница 1: ...TY JS 220308 001 1 CW 5000 5200 Industrial Chiller User Manual...

Страница 2: ...rly so that you can refer to it whenever you need information This manual is not a quality guarantee Our company reserves the right to the interpretation of the correction of misprint and improperly d...

Страница 3: ...NTENTS Notice 4 I Overview 7 II Model Illustration 7 III Product Outlines Parts 8 IV Installation 9 V Operating States Parameters Adjustment 11 VI Alarm Output Terminal 13 VII Maintenance 14 VIII Simp...

Страница 4: ...on a The power supply must conform to the standard indicated in the nameplate or the manual b Use the standard cable and select the standard wire diameter c The grounding wire must be installed and th...

Страница 5: ...ailable Otherwise it may cause anesthesia and suffocation if a large amount of refrigerant fills the enclosed space b Avoid contacting with skin or it will cause frostbite DANGER Failure to take safet...

Страница 6: ...r filter at least once a week If it is blocked the cooling ability will decrease and the power consumption will increase and the alarm will not work properly Equipment surface cleaning a Please use cl...

Страница 7: ...chiller the refrigerant in the evaporator coil absorbs the heat of the return water and vaporizes into steam The compressor continuously extracts the generated steam from the evaporator and compresses...

Страница 8: ...rt names are only for one of the models and they will be slightly different in different models POWER SWITCH TEMPERATURE CONTROLLER AIR INLET FILTER GAUZE ALARM OUTPUT TERMINAL COOLING WATER OUTLET CO...

Страница 9: ...Requirements Cooling medium allowed by the chiller includes purified water distilled water high purity water and other softened water It is forbidden to use oily liquids liquids containing solid part...

Страница 10: ...on 1 Please select the cable based on the max rated current indicated on the label of the chiller 2 Recommended reference standard for power cord diameter selection Rated current A 5 10 15 25 35 50 Wi...

Страница 11: ...trolling parameters according to room temperature for meeting equipment cooling requirements The new T 504D intelligent temperature controller is selected constant temperature control mode as factory...

Страница 12: ...ey to change settings After modifying the value press the ENTER button RST to save and exit then new parameters take effect or press SET key SET to exit without saving parameters If there is no more a...

Страница 13: ...the ambient the fluctuation will not exceed 0 5 There will be an alert when water temperature is 10 lower or higher than target e g when ambient temperature is 30 0 cooling water temperature is betwe...

Страница 14: ...the air filter must not be missing for a long time VIII Simple Troubleshooting Failure Failure Cause Approach Machine turned on but unelectrified Power cord is not plugged in place Check and ensure th...

Страница 15: ...tlet and inlet To ensure a smooth ventilation for air outlet and inlet Voltage is extremely low or astable To improve the power supply circuit or use a voltage regulator Improper parameter settings on...

Отзывы: