4-31
Parameters
Functions
Settings
Factory
Setting
Customer
10-19
Loop
Point
0~20000
10
10-20
Division (scaling) factor
for PG04/05
1~128
1
10-21
Feed
Forward
0.0~100.0%
5.0
10-22
Position Control Speed
Gain
0.0~100.0%
90.0
10-23
PG Position Attained 2
0 ~ 20000
0
10-24
P2P
Acceleration
Time
0.00 ~ 100.00 s
0.1
10-25
P2P
Deceleration
Time 0.00 ~ 100.00 s
0.1
10-26
Delay Time for Position
Command
0.00 ~ 100.00 s
0.1
10-27
Position Control P Gain
2
0.0 ~ 1500.0% (05-25 switch)
50.0
10-28
Position Control Integral
(I) Time 2
0.001 ~ 10.000 s
000: no integral (0.5-25 switch)
0.050
10-29
Selection of P2P Control
Mode
0: relative P2P
1: absolute P2P
0
10-30
Direction Command of
Absolute P2P
0~255 (10-33~40)
0
10-31
FWD Limit of Absolute
P2P
1~60000
0: No Limit
0
10-32
REV Limit of Absolute
P2P
1~60000
0: No Limit
0
10-33
P2P Command 0
0~50000 (in position control 2
mode)
0
10-34
P2P Command 1
0~50000 (in position control 2
mode)
0
10-35
P2P Command 2
0~50000 (in position control 2
mode)
0
10-36
P2P Command 3
0~50000 (in position control 2
mode)
0
10-37
P2P Command 4
0~50000 (in position control 2
mode)
0
10-38
P2P Command 5
0~50000 (in position control 2
mode)
0
10-39
P2P Command 6
0~50000 (in position control 2
mode)
0
10-40
P2P Command 7
0~50000 (in position control 2
mode)
0
Содержание S3000 Series
Страница 1: ...440V Series Multifunctional VectorControl ACMotor Drivers User Manual S3000 Series AC Motor Drivers...
Страница 8: ...2 5 DIMENTIONS 2 5...
Страница 9: ...2 6 403 216...
Страница 10: ...2 7...
Страница 11: ...2 8 S3000 IP06...