4-10
Group 2: Digital Output/Input Parameter
Parameters
Functions
Settings
Factory
Setting
Customer
02-00
2-Wire/3-Wire
Operation Control
0: FWD/STOP, REV/STOP
1: FWD/STOP, REV/STOP (Line
Start Lockout)
2: RUN/STOP, REV/FWD
3: RUN/STOP, REV/FWD (Line
Start Lockout)
4: 3-wire (momentary push
button)
5: 3-wire (momentary push
button and Line Start
Lockout)
0
02-01
Multi-Function Input
Command 1 (MI1)
0: no function
1: multi-step speed command 1
2: multi-step speed command 2
3: multi-step speed command 3
4: multi-step speed command 4
5: Reset
1
02-02
Multi-Function Input
Command 2 (MI2)
2
02-03
Multi-Function Input
Command 3 (MI3)
6: JOG command
7: acceleration/deceleration
speed inhibit
8: the 1
st
, 2
nd
acceleration/deceleration
time selection
9: the 3
rd
, 4
th
acceleration/deceleration
time selection
10: EF input
11: disable vector(stop)
3
02-04
Multi-Function Input
Command 4 (MI4)
4
02-05
Multi-Function Input
Command 5 (MI5)
12: B.B. traces from the bottom
upward
13: B.B. traces from the top
downward
14: cancel the setting of the
optimal
acceleration/deceleration
time
15: switch between drive
settings 1 and 2
16: operation speed command
from AVI
5