34
5.18 Input TCP/IP Address
This function is to input TCP/IP address for TCP transmission. Please note that data will only be uploaded to this TCP/IP
address when TCP transmission mode is selected. The SMS command is as following:
Setup format
:
#
「
username
」
,
「
Password
」
,
「
Function Code
」
,
「
TCP/IP Address
」
*
Example
:
#username,0000,17, 210.242.12.73*
The table 5.18.1 describes the meaning of each segment in the message above.
Table 5.18.1
The table 5.18.2 shows each confirmation message reply after setup.
Table 5.18.2
Text Keyed In SMS
Description
#
Start sign.
username
Default ID of GC-101S.
If you have changed the Username, please use the updated one.
0000
Default password.
If you have changed the password, please use the updated one.
17
Function code
210.242.12.73
TCP/IP Address
*
End sign.
Situation
Message Reply
Setup Succeeds
[username] +", setup ok. Device TCP/IP is updated."
Setup Fail
[username] +", TCP/IP setup fail!"
GC-101S is in Emergency Mode
[username] + "in emergency, TCP/IP is not allowed."
Incorrect username or password
[username] + Username or Password error
Incorrect function code
[username] + command error