31
Geofence Alarm Report:
This command is to define the report interval when Geofence is triggered.
Setup format
:
#
「
username
」
,
「
Password
」
,
「
Function Code
」
,
「
Time Interval
」
,
「
Total Report
」
*
Command: #username,0000,17,60,12*
Text Keyed In SMS
Description
#
Start sign.
username
Default ID of GC-101.
If you have changed the Username, please use the updated one.
0000
Default password.
If you have changed the password, please use the updated one.
17
Mode 17 is the Geofence report interval setting
0~32,000
Time interval in second
0~9999
Total report. Note that 9999 means infinite reporting.
*
End sign.