MP9320 User’s Guide
52
Changing Reader Configuration
To setup a SAMSys reader, the Configuration Write (Cw)
command is used to write a three-letter configuration variable
name and a 32-bit word to the reader. This word contains the
individual setup parameters required by the reader.
For specific syntax information on the Configuration Write
command refer to Chapter 2 in the
Comprehensive Heuristic
Unified Messaging Protocol Reference Guide
.
Commonly used configuration variables include the following:
•
GCW – General Configuration Word
•
SCW – Serial Configuration Word (CHUMP 1.31 and above)
•
MCW – Multiplexer Configuration Word
•
SMA – Serial Multidrop Address
•
PCW – Protocol Configuration Word
•
PSW – Protocol Select Word
•
Pxx – Specific Protocol Configurations
The following example shows the Cw command used to write the
MCW to the reader.
}Cw,d:MCW,b:00040200! <CRLF>
where:
00040200 = 4 antennas, 2 inventory
round operations per antenna.
If the Cw command was successful, the reader responds with the
following:
{A7; <FCS><CRLF>