Troubleshooting
37
Symptom
Probable Cause
Corrective Action
No LEDs or
buzzer during
power up.
Power supply
malfunction.
Ensure power supply is
inserted into wall outlet. Verify
correct operating voltage at
outlet.
Replace Power Supply.
Reader software is
corrupt.
Replace reader.
Reader appears
to lock up.
Readers are
vulnerable to high
ESD pulses. As a
result, the reader
can lock up.
Disconnect the power from the
reader and reconnect. The
reader should reset. If the
reader does not function
normally after reset, replace
the reader.
Any LED fails
and buzzer
alarms during
power up.
Suspect LED bad.
Reader may operate normally
with one or more bad LEDs,
but the reader should be
replaced as soon as possible.
Reader board
failure.
If reader does not read or write,
replace the reader.
No buzzer on
power up.
Buzzer malfunction. Reader may operate normally
without buzzer, but the reader
should be replaced as soon as
possible.
Reader board
failure.
If reader does not read or write,
replace the reader.
Reader software is
corrupt.
Replace reader.
No buzzer when
reading a tag.
Buzzer malfunction. Reader may operate normally
without buzzer, but the reader
should be replaced as soon as
possible.
Reader board
failure.
If the reader does not read or
write, replace the reader.
Reader software is
corrupt.
Replace reader.
Содержание MP9320
Страница 1: ...User s Guide MP9320 UHF Long Range Reader...
Страница 2: ......
Страница 8: ...MP9320 User s Guide iv...
Страница 42: ...MP9320 User s Guide 34...
Страница 47: ...Troubleshooting 39 Telephone 1 877 367 4342 toll free 8 00am 6 00pm EST Mon Fri Fax 1 919 281 1551...
Страница 48: ...MP9320 User s Guide 40...
Страница 56: ...MP9320 User s Guide 48...
Страница 64: ...MP9320 User s Guide 56...
Страница 65: ......
Страница 66: ...SAMSys Technologies Inc Part Number HI46932 01 OM V3 2 Printed in U S A...