I/O time setup
I/O time setup
DOOR OPEN TIMEOUT SETUP
You can set the alarm to sound if the door stays open after a specifi c wait time from when it opens.
Press the
F
5
SETUP MENU button.
Use the buttons
4
and
6
to move to the
DOOR TIME OUT
item and
press
ENT
.
You can make input when the prompt blinks.
Use the keypad to enter the time for each output operation and press
ENT
.
DR : Door relay output
AR : Alarm relay output
T1 : TTL #1 output
T2 : TTL #2 output
BZ : Buzzer output
The output time differs, depending on the time unit.
If the time unit is 0.1 (second), you can specify the value between 0.0 and 9.8 second; if set to 1 (second), you can
specify between 0 and 98 seconds.
For the time unit, refer to the ‘Time Unit Setup’ under the advanced setup. (see page 54)
If you enter 99 for the value, the product stays in output mode until you change the setting regardless of the time
unit.
OUTPUT SETUP FOR LEVEL IDs ACCESSING READER #1
Output Setup for the event of Level 1 IDs accessing the READER #1
Press the
F
6
SETUP MENU button.
Use the buttons
4
and
6
to move to the
RD1 ID OK LV1
item and
press
ENT
.
You can make input when the prompt blinks.
Use the keypad to enter the time for each output operation and press
ENT
.
DR : Door relay output
AR : Alarm relay output
T1 : TTL #1 output
T2 : TTL #2 output
BZ : Buzzer output
The output time differs, depending on the time unit.
If the time unit is 0.1 (second), you can specify the value between 0.0 and 9.8 second; if set to 1 (second), you can
specify between 0 and 98 seconds.
For the time unit, refer to the ‘Time Unit Setup’ under the advanced setup. (see page 54)
If you enter 99 for the value, the product stays in output mode until you change the setting regardless of the time
unit.
1.
2.
3.
•
M
1.
2.
3.
•
M
9.DOOR TIME OUT
D R A R T 1 T 2 B Z
0 0 9 9 0 0 0 0 0 0
9.DOOR TIME OUT
D R A R T 1 T 2 B Z
_ 0 9 9 0 0 0 0 0 0
1.RD1 ID OK LV1
D R A R T 1 T 2 B Z
0 3 0 0 0 0 0 0 0 0
1.RD1 ID OK LV1
D R A R T 1 T 2 B Z
_ 3 0 0 0 0 0 0 0 0