P (Priority) :
Set the priority of Alarm Inputs. If more than one alarm is simultaneously activated,
the alarm with the highest priority activates before the others. Once the alarm is canceled, the
next highest priority alarm activates.
SEQ :
Enables setting up a sequence action for the camera in response to an alarm. Available
sequence actions are Preset, Swing, Group, Tour, Trace and A.Pan.
•Asshowninthepictureabove,theAlarmInputmustbeenteredwiththeOpenorClosed
switch signals. Supplying power without entering the signals may damage the product.
Notes
Alarm Output
Output
□
1
□
2
□
3
□
MD
□
TRK
Time
OFF
Alarm Setting
Alarm Enable
OFF
②
Alarm Input
③
Alarm Output
④
Aux Output
Main Menu
①
Camera Setting
②
Sequence Setting
③
P/T Setting
④
OSD Setting
⑤
Alarm Setting
⑥
Initialize
Status
➡
➡
25.2. Alarm Output
▶
Main Menu/Alarm Setting/Alarm Output
Setting :
Enables selecting an Alarm Output method.
- 1, 2, 3 and MD on the menu selection indicate the alarm
input port and motion detection input. Up to 3 alarm
inputs can be set for each MD (Motion Detection) and
TRK (Auto Track). Alarm output port can be used for more
than 2 alarm inputs along with ones for MD and TRK.
Time :
Enables selecting an Alarm Output method.
- On : Retains an alarm output for a set duration from a
minimum of 1 second to a maximum of 60 hours
upon the alarm occurrence.
- Momentary : Retains an alarm output only until the alarm
is canceled.
✽
The TRK function becomes activated only if the Zone mode
under Zone Settings under Auto Track 2 is set to Alarm.
✽
The Alarm Output is equipped with a relay circuit. The
operation of the alarm output port is as shown in the
diagram below.
•ConnectingthepowerconnectorandGNDincorrectlytotheNC/NOandCOMportsmay
cause a short circuit and fire, damaging the camera.
•Themaximumpowercapacityofthebuilt-inrelayis30VDC/2A,125VAC/0.5A,and
250VAC/0.25A. Operating the camera beyond the capacity may decrease the camera’s
lifespan and damage it.
Notes
⇨
NO
NO
NC
NC
COM
COM
Alarm Out OFF
Alarm Out ON