5-23
[5] Trunk Signal
Function
You can set the signal type for analog and digital trunk.
Procedure
1. In the <PSTN Configuration Menu> screen, type ‘5’, and press [Enter].
<<<<< Trunk Signal >>>>>
+---+-------------------+---------------+---------+
| No | Trunk Signal Type
| Value
| Default
|
+---+-------------------+---------------+---------+
| 0
| Insert End Of Digit
| Off
| Off
|
+---+-------------------+------+--------+---------+
+---+-------------------+------+--------+---------+
| No | Trunk Signal Timer
| Value
| Unit
| Default
|
+---+-------------------+------+--------+---------+
| 1
| Seize Time
| 30
| 10 msec
| 30
|
| 2
| Release Time
| 10
| 100 msec
| 10
|
| 3
| Noring Time
| 4
| 1 sec
| 4
|
| 4
| Answer Holding Time
| 6
| 100 msec
| 6
|
| 5
| CO HookOn Time
| 200
| 10 msec
| 200
|
+---+-------------------+------+---------+--------+
[ . :Exit ]
2. Input the number of the trunk signal type to be changed, and press [Enter].
Configuration Item Number: