User’s Manual
30
Figure 35 — PTZ Device list.
You can assign IDs to each camera by highlighting the
ID
heading and pressing the
button.
Change the number by highlighting it and using the
Up
and
Down
arrow buttons to increase and
decrease the number. The PTZ ID number can be set from 0 to 256.
Alarm In Setup Screen
Highlight
Alarm In
in the Main menu and press the
button. The
Alarm In
setup screen
appears.
Figure 36 — Alarm In setup screen.
The alarm terminal strip on the back of the DVR has inputs associated with each alarm. You
can set up each input on the
Alarm In
Setup
screen. The inputs are displayed in groups of four.
You can turn each input On or
Off
. Each input can be given a title, and the inputs can be set as
NO
(normally open) or
NC
(normally closed) independently.