Deciding on where to install the indoor unit
Indoor unit
There must be no obstacles near the air inlet and outlet.
Install the indoor unit on a ceiling that can support its weight.
Maintain sufficient clearance around the indoor unit.
Make sure that the water dripping from the drain hose runs away correctly
and safely.
The indoor unit must be installed in this way, that they are out of public
access. (Not touchable by the users)
Space requirements for indoor unit
Avoid installing the air conditioner:
In areas where it is exposed to direct sunlight. Close to heat sources.
In damp areas or locations where it could come into contact with water.
(for example rooms used for laundry)
In areas where curtains and furniture could affect the supply and discharge of air.
Without leaving the required minimum space around the unit. (as shown in the
drawing)
In scarcely ventilated areas.
On surfaces that are unable to support the weight of the unit without deforming,
breaking or causing vibrations during the use of the air conditioner.
In a position that does not enable the condensate drainage pipe to be correctly
installed. (at the end of the installation. It is always essential to check the efficiency
of the drainage system)
The units must be installed according to distances declared, in order to
permit accessibility from each side, either to guarantee correct operation
of maintenance or repairing products.
The unit’s parts must be reachable and removable completely under safety
condition (for people or things).
CAUTION
As a rule, the unit cannot be installed at a height of less than 2.5 m.
It is possible to install the unit at a height of between 2.2~2.5m from
the ground, if the unit has a duct with a well defined length (300mm
or more) to avoid fan motor blower contact.
CAUTION