E-
16
Troubleshooting
Detection of errors
LED Display on the receiver & display unit
LED Display
Abnormal conditions
LED lamp display
Remarks
Power reset
X
X
X
Error of temperature sensor
in the indoor unitt (Open/Short)
X
X
X
Displays an error on the related
indoor unit.
Error of heat exchanger sensor
in the indoor unit
X
X
Displays an error on the related
indoor unit.
Error of indoor fan motor:
(Keeps running below 450RPM for
15 seconds)
X
X
X
Confirm the connections of
CN73 and CN44.
Error of the outdoor temperature sensor
Error of the condensor temperature sensor
Error of the discharge temperature sensor
(Open/Short)
X
X
1. No communication for 2 minutes
between indoor units
(Communication error for more than 2 minutes)
2. Indoor unit receiving the
communication error from outdoor unit
3. Outdoor unit tracking 3 minutes error
4. When sending the communication
error from the outdoor unit, the
mismatching of the communication
numbers and installed numbers after
completion of tracking
(Communication error for more than 2 minutes)
X
X
1. Indoor unit error
(Display is unrelated with
operation)
2. Outdoor unit error
(Display is unrelated with
operation)
If you turn off the air conditioner when the LED is flickering, the LED is also turned off.
On Flickering X Off
If an error occurs during the operation, one or more LED flickers and the operation is stopped except the LED.
If you re-operate the air conditioner, it operates normally at first, then detect an error again.