- 65/65 -
Step 3
(DEFROST SENSOR)
① No freezing on the bottom of EVAP,
top+
DEFROST SENSOR are being ice.
② Inspect and replace DEFROST SENSOR
open.
Step 4
(DEFROST SENSOR sensing location
problem)
① No freezing on bottom of EVAP, EVAP top +
DEFROST SENSOR part don’t have freezing
② Move and fix the DEFROST SENSOR
location to freezing part.
Step 6
(HEATER location problem)
① When the EVAP BOTTOM freezes only
- Improve DRAIN freezing.
② Check the drain hole blocking
with remove
freezing using STEAMER.
(Remove DRAIN freezing and foreign
substance)
③ DRAIN FIXER should be on CENTER.
④ Bending the HEATER into Bottom using
hand.
- DRAIN HOLE should be closed
.
★ HEATER can not contact to PLATE.
Step 7
(Total inspect after defrost repairing)
① Check the HEATER operation with forced
defrost after complete repairing
.
Touch “Energy Saver+Fridge” for 8sec at the
same time to off ALL LEDs and touch the
“Fridge”
key for 4 times to operate “Fd”
.
Check the HEATER(Brown-wire) AC voltage
supplying when “beep” sound occur.
② Off same way if there is no problem.
EVAP top+ Sensor freezing
No freezing on EVAP top
f Sensor
SENSOR
보임
MOVE