- 60/65 -
Tip 9-2. Inspect cooling power
(
※
Must select “Power
Freeze” first)
※ Do not off the power
Measure self-diagnosis test
inspection on“TIP 2-4”
Step 1
Touch Display “Energy Saver”+ “Alarm” Key for 8
sec at the same time.
- Touch it until “dingdong” sound occur after all
LEDs blink.
※ When Error appears
Move to TIP 2-4
-No problem
Inspect Step 2
Step 2
(Comp Operation inspection)
① Touch Display “Freezer” for 3set to make
“Power Freeze”.
※ Setting temperature satisfaction and
defrost performance Comp Off.
(If the COMP operate again, off as 8 min.
and operate it)
② Inspect the operation of backside Comp.
(Check operation condition using hand
touching Comp)
- If the Comp doesn’t operate
See Step 3
- If the Comp operate
Inspect Step 6
Step 3
(Inspect Comp Wire )
① Inspect the Backside Unit left-side Comp
Wire Connector assembly problem
② Inspect OLP & inver wire after disassemble
Comp leftside Relay Cover
③ If the all things are normal, move the Tip 2-4
comp error inspection click.
Connector
separation
Relay
separation