Step 1
Touch Display ”Energy Saver”+“Alarm” Key at the
same time for 8 sec until “DingDong” sound
occur
※ When Error occurs
Measure with moving
TIP 5-1.
-
When the ERROR does not exist, “25 E”(R
DEFROST ERROR)
Check Step2
Step 2
(Bimetal / HEATER OPEN)
① Inspect BIMETAL (RED+BLK) Open
Replace the part
- Normal: 0Ω,
Failure: OPEN
② Measure Heater (BRN+BRN)resistance
Replace Heater
- Normal: 90~115Ω,
- Failure : Open & 0 Ω
③ Voltage of forced Heater On HEATER
part
WIRE inspection
- Normal:105~125V,
Failure: 0V
④ Main PBA CN70 7번(WHT),CN72번 3번GRY)
+LINER 부 CONNECTOR WIRE OPEN 점검
Tip 5-2. Inspect R room EVAP DEFROST BUILD
※ Do not Off the power and operate Self-diagnosis test for “TIP 5-1”
first.
Must check forced defrost operation after repair defrosting.
Freezing occurs on all of the EVAP
CN 70 CN 72
Inspect
Bimetal
resistance
Inspect
HEATER
resistance
Next Page