Step 3
(DEFROST SENSOR)
① No freezing on the bottom of EVAP,
Top+
DEFROST SENSOR have ice.
② Inspection and replace DEFROST SENSOR
open.
Step 4
(DEFROST SENSOR Sensing location
problem)
① No freezing on the bottom of EVAP, EVAP top
+
DEFROST SENSOR part don’t have
freezing
② Move the location of DEFROST SENSOR to
freezing part.
Step 6
(HEATER location problem)
① When freezing on EVAP BOTTOM
- Improve DRAIN freezing.
② Remove freezing with STEAMER
and check
DRAIN HOLE blocking.
(Remove DRAIN freezing and foreign
substance)
③ DRAIN FIXER should be on CENTER.
④ Bending the HATER with hand into bottom.
- DRAIN HOLE should be closed
.
★ HEATER can not contact to PLATE.
Step 7
(Total inspection after defrost reparing)
① Check the HEATER operation with forced
defrost operation after complete repairing
.
Touch “Energy Saver+Fridge” for 8 sec at the
same time and operate
“Fd”
with touching
“Fridge” key 4 times after All LED off.
Check the HEATER (Brown-wire) AC
voltage supplies when “beep“ sounds.
② Off with same way if there is no problem
EVAP Top + Sensor Freezing
EVAP top freezing
+ No Sensor freezing
Locate
Sensor
MOVE