- 3/65 -
●
Ice
#1. Symptom : No Ice Repair distribution diagram
Check-1
Reason Step
Check-2
Tip
Code
Block
# 1
# 2
# 3
Ice Bucket
Full
(Dispensing
problem)
Display Issue
Inspect Display Water
& Ice selecting
1-1
Panel-
PBA
Wire
Harness
Main
PBA
Lever S/W problem
Inspect Lever S/W
operation
1-2
Panel-
PBA
Wire
Harness
Ice
Bucket
Auger
Motor
S/W
Wire
Harness
Auger S/W failure
Inspect Auger Motor
S/W operation
Auger Motor Prob
Inspect ASSY
Auger Motor
operation
1-3
ASSY
Auger
Motor
Wire
Harness
Main
PBA
Ice Bucket
Empty
(Ice making
problem)
Ice maker water
supply issue
Inspect Water
connection / supply
2-1 External
Conn.
(water
supply)
Water
Hose
Filter
Ice Full sensing
failure
2-2
IR
Sensor
Wire
Inspect Ice Valve
operation
2-3
Wire
Harness
Ice Valve
Ice maker/ Sensor
/ Fan Motor issue
Self-diagnosis
Display “Energy
Saver” +”Alarm”
2-4
Ice
Maker,
Sensor,
Fan
Damper
Wire
Harness
Main
PBA
Cooling power
failure
(Ice melting
in Tray)
Measure cooling
power inspection
Comp / Fan motor
inspection
2-5
Comp
Relay
Cycle
Shield
System
C-fan
Chassis
Project
Basic Model
Type
FDR
AW1-12
RF263*
Direct Ice Maker
※
Check the Display as “ICE off”
Содержание RF263