- 64/65 -
Step 1
Touch Display ”Energy Saver”+“Alarm” Key for
8sec at the same time until “Ding Dong” sound
occur.
※ When the Error occur
Measure to TIP
5-1.
- No
ERROR, “24 E”(F DEFROST ERROR)
Check Step2
Step 2
(Bimetal / HEATER OPEN)
① Inspect BIMETAL (RED+BLK) Open
replace part
- Normal: 0Ω,
Failure: OPEN
② Measure Heater (BRN+BRN) resistance
Replace Heater
- Normal : 50~72Ω,
- failure : Open & 0 Ω
③ Forced Heater On HEATER part
voltage
check WIRE
- Normal:105~125V,
Failure: 0V
④ Inspect Main PBA CN70 No.9(BRN),CN72
No.3GRY)+LINER part CONNECTOR WIRE
OPEN
Tip 9-4. Inspect F EVAP DEFROST BUILD
※ Operate self-diagnosis test on “TIP 5-1” first without power off.
Must check forced defrost operation after defrost repairing.
All EVAP freezing
CN 70 CN 72
Inspect BIMETAL
resistance
Inspect HEATER resistance
Next Page